Elit logo e-Elit - leading
electronic and automation component
online distributor
Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
AC Line Filter, Ultra3000 drive, 23A 250VAC, power loss 10W, Allen-Bradley
AC Line Filter, Ultra3000 drive, 23A 250VAC, power loss 10W, Allen-Bradley



Simatic ET 200SP, Digital Input Module, 8DI 24VDC, type 3 (IEC 61131), sink input, (PNP, P-reading), fits BU-type A0, color code CC01, input delay time 0.05..20ms, module diagnostics for short-circuiting of sensor supply, wire break, supply voltage,
Image is illustrative
Simatic ET 200SP, Digital Input Module, 8DI 24VDC, type 3 (IEC 61131), sink input, (PNP, P-reading), fits BU-type A0, color code CC01, input delay time 0.05..20ms, module diagnostics for short-circuiting of sensor supply, wire break, supply voltage,
Code: 6ES7131-6BF01-0BA0
Cena (indicative)
62,00 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.0389 kg/pc
Volume:
0.0001 m3/pc
Quantity:
Plus sign Minus sign
 

 

Simatic ET 200SP, Digital Input Module, 8DI 24VDC, type 3 (IEC 61131), sink input, (PNP, P-reading), fits to BU-type A0, colour code CC01, input delay time 0.05..20ms, module diagnostics for: short-circuit of sensor supply, wire break, supply voltage, Sie

SIMATIC ET 200SP, Digital input module, DI 8x 24V DC Standard, type 3 (IEC 61131), sink input, (PNP, P-reading), Packing unit: 1 piece, fits to BU-type A0, Colour Code CC01, input delay time 0,05..20ms, module diagnostics for: short-circuit of sensor supply, wire break, supply voltage
General information
Product type designation DI 8x24 VDC ST
Firmware version V0.0
● FW update possible No
usable BaseUnits BU type A0
Color code for module-specific color identification plate CC01
Product function
● I&M data Yes; I&M0 to I&M3
Engineering with
● STEP 7 TIA Portal configurable/integrated as of version V14
● STEP 7 configurable/integrated as of version V5.5 SP3 or higher
● PCS 7 configurable/integrated as of version V8.1 SP1
● PROFIBUS as of GSD version/GSD revision One GSD file each, Revision 3 and 5 and higher
● PROFINET as of GSD version/GSD revision GSDML V2.3
Operating mode
● DI Yes
● Counter No
● Oversampling No
● MSI No
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption, max. 50 mA; All channels are supplied from the encoder supply
Encoder supply
Number of outputs 8
Output voltage encoder supply, min. 19.2 V
Short-circuit protection Yes; per module
24 V encoder supply
● 24 V Yes
● Short-circuit protection Yes
● Output current, max. 700 mA; Total current of all encoders
● Output current per channel, max. 700 mA
● Output current per module, max. 700 mA
Power loss
Power loss, typ. 1 W; 24 V, 8 inputs supplied via encoder supply
Address area
Address space per module
● Inputs 1 byte; + 1 byte for QI information
Hardware configuration
Automatic encoding Yes
● Mechanical coding element Yes
Submodules
● Number of configurable submodules, max. 4
Selection of BaseUnit for connection variants
● 1-wire connection BU type A0
● 2-wire connection BU type A0
● 3-wire connection BU type A0 with AUX terminals
● 4-wire connection BU type A0 + Potential isolation module
Digital inputs
Number of digital inputs 8
Digital inputs, parameterizable Yes
Source/sink input P-reading
Input characteristic curve in accordance with IEC 61131, type 3 Yes
Input voltage
● Type of input voltage DC
● Rated value (DC) 24 V
● for signal "0" -30 to +5V
● for signal "1" +11 to +30V
Input current
● for signal "1", typ. 2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable Yes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms (in each case + delay of 30 to 500 µs, depending on line length)
— at "0" to "1", min. 0.05 ms
— at "0" to "1", max. 20 ms
— at "1" to "0", min. 0.05 ms
— at "1" to "0", max. 20 ms
Cable length
● shielded, max. 1 000 m
● unshielded, max. 600 m
Encoder
Connectable encoders
● 2-wire sensor Yes
— permissible quiescent current (2-wire sensor), max. 1.5 mA
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Diagnostics function Yes
Alarms
● Diagnostic alarm Yes
Diagnostic messages
● Diagnostic information readable Yes
● Monitoring the supply voltage Yes
— parameterizable Yes
● Monitoring of encoder power supply Yes; Module-by-module, optional protective circuit for preventing wire-break diagnostics in the case of simple encoder contacts: 25 kOhm to 45 kOhm
● Wire-break Yes; Module-wise
● Short-circuit Yes; Module-wise
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● Channel status display Yes; Green LED
● for channel diagnostics No
● for module diagnostics Yes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channels No
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics No
Isolation
Isolation tested with 707 V DC (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C
● horizontal installation, max. 60 °C
● vertical installation, min. 0 °C
● vertical installation, max. 50 °C
Altitude during operation relating to sea level
● Ambient air temperature-barometric pressure-altitude On request: Ambient temperatures lower than 0 °C (without condensation) and/or installation altitudes greater than 2 000 m
Dimensions
Width 15 mm
Height 73 mm
Depth 58 mm
Weights
Weight, approx. 28 g