|
|
Image is illustrative
|
Control Unit Guardmaster Sipha, 1NO safety, 24VAC/DC, 1NC aux., Allen-Bradley Code:
440N-S32013
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.174 kg/pc
|
Volume:
0.0006 m3/pc
|
|
|
|
|
Control Unit Guardmaster Sipha, 1NO safety, 24VAC/DC, 1NC aux., Allen-Bradley
DESCRIPTIONS
-
Guardmaster® Sipha™ Control Unit, Type: Type 1, Voltage Rating: 24 VAC/VDC, Contact Configuration: 1NO Safety, 1NC Auxiliary, Size: 0.89 IN Width X 3.23 IN Height X 3.9 IN Depth, Mounting: 35 MM DIN Rail, Operating Cycles: Electrical: 220 VAC/4 A: 0.35 - 0.1 Million, 220 VAC/1.7 A: 0.6 - 0.5 Million, 30 VDC/2 A/60 W: 1 Million, 10 VDC/0.01 A/0.1 W: 2 Million, Mechanical: 2000000, Temperature Rating: -10 To 55 DEG C, Environmental Conditions: Vibration: 1 MM, 10 - 55 HZ, Shock: 30 G, 11 MS Half-Sine, Cable Size: 24 - 14 AWG, Coil Voltage: 24 VAC/VDC, Housing: 22.5 MM, Withstand Voltage: 2500 V, Switching Current: 10 MA At 10 V, Power Consumption: Less Than 2 VA, Resistance: Terminals 1 - 4: 200 OHM, Terminals 2 - 3: 150 OHM
SPECIFICATIONS
-
-
Item Name: Control Unit
-
Type: Type 1
-
Sub Brand: Guardmaster®, Sipha™
-
Voltage Rating: 24 VAC/VDC
-
Contact Configuration: 1NO Safety, 1NC Auxiliary
-
Size: 0.89 IN Width X 3.23 IN Height X 3.9 IN Depth
-
Mounting: 35 MM DIN Rail
-
Operating Cycles: Electrical: 220 VAC/4 A: 0.35 - 0.1 Million, 220 VAC/1.7 A: 0.6 - 0.5 Million, 30 VDC/2 A/60 W: 1 Million, 10 VDC/0.01 A/0.1 W: 2 Million, Mechanical: 2000000
-
Temperature Rating: -10 To 55 DEG C
-
Environmental Conditions: Vibration: 1 MM, 10 - 55 HZ, Shock: 30 G, 11 MS Half-Sine
-
Cable Size: 24 - 14 AWG
-
Coil Voltage: 24 VAC/VDC
-
Switching Current: 10 MA At 10 V
-
Housing: 22.5 MM
-
Withstand Voltage: 2500 V
-
Power Consumption: Less Than 2 VA
-
Resistance: Terminals 1 - 4: 200 OHM, Terminals 2 - 3: 150 OHM
FEATURES
-
With the increasing speed and complexity of applications a simple magnetic switch may be insufficient to meet the increased risks, therefore Sipha’s design incorporates several magnetically sensitive elements which must be triggered in a particular sequence to operate correctly. The Sipha sensor, designed to operate with its own actuator, helps prevent defeatability by a simple magnet. - Noncontact actuation
- Magnetic coded sensing
- Control unit acts as safety relay
- Four types of switches
- External 5 A quick blow AC, 3 A quick blow DC fuses output
- Standards: EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/EN60947-5-1, ANSI B11.19, AS4024.1, CE Marked for all applicable directives, cULus, and TUV
- Applications: Designed to operate with the Sipha sensors and actuators
|
|
|
|