Image is illustrative
|
Electronically Fused Output Module ControlLogix, 10-31VDC, 16-points (20 Pin), Rockwell Automation Code:
1756-OB16E
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.322 kg/pc
|
Volume:
0.0024 m3/pc
|
|
|
|
|
Electronically Fused Output Module ControlLogix, 10-31VDC, 16-points (20 Pin), Rockwell Automation
DESCRIPTIONS
-
ControlLogix® Digital DC Output Module, Number Of Channels: 16, Output: Operating Voltage: 10 - 31.2 VDC, On-State Voltage Drop: 400 M VDC At 1 A, Voltage Rating: 12/24 VDC, Current Rating: Drawn: 250 MA At 5.1 V, 2 MA At 24 V, Off-State Leakage Current Per Point: 1 MA Per Point, Current Per Point: 1 A At 60 DEG C, Current Per Module: 8 A At 60 DEG C, Load Current: 3 MA Per Point, Isolation: 250 V (Continuous), Basic Insulation Type, Outputs-To-Backplane, And Output Group-To-Group, No Isolation Between Individual Group Output, 1350 VAC For 2 SEC Routine Test, Power Rating: Backplane: 1.32 W, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Display: Output, Fault And Communication Status, Module Health, Interface: Removable Terminal Block, Mounting: Chassis, Width: 1-23/64 IN, Height: 5-11/16 IN, Temperature Rating: 32 - 140 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock: 30 G(Operating), 50 G (Non-Operating), Response Time: Delay (Off To On): 70 MIC-SEC Nominal/1 MS Maximum, Delay (On To Off): 360 MIC-SEC Nominal/5 MS Maximum, Power Dissipation: 4.1 W At 60 DEG C, Output Type: Current Sourcing, Slot Width: 1, Surge Current: 2 A For 10 MS/Point, Repeatable Every 2 SEC At 60 DEG C, Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports, Standard/Approvals: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, CE-LVD, C-TICK, FM-US_HAZ, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR
SPECIFICATIONS
-
-
Item Name: Digital DC Output Module
-
Sub Brand: ControlLogix®
-
Number Of Channels: 16
-
Output: Operating Voltage: 10 - 31.2 VDC, On-State Voltage Drop: 400 M VDC At 1 A
-
Voltage Rating: 12/24 VDC
-
Current Rating: Drawn: 250 MA At 5.1 V, 2 MA At 24 V, Off-State Leakage Current Per Point: 1 MA Per Point, Current Per Point: 1 A At 60 DEG C, Current Per Module: 8 A At 60 DEG C, Load Current: 3 MA Per Point
-
Isolation: 250 V (Continuous), Basic Insulation Type, Outputs-To-Backplane, And Output Group-To-Group, No Isolation Between Individual Group Output, 1350 VAC For 2 SEC Routine Test
-
Power Rating: Backplane: 1.32 W
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Display: Output, Fault And Communication Status, Module Health
-
Interface: Removable Terminal Block
-
Mounting: Chassis
-
Width: 1-23/64 IN
-
Height: 5-11/16 IN
-
Temperature Rating: 32 - 140 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock: 30 G(Operating), 50 G (Non-Operating)
-
Response Time: Delay (Off To On): 70 MIC-SEC Nominal/1 MS Maximum, Delay (On To Off): 360 MIC-SEC Nominal/5 MS Maximum
-
Power Dissipation: 4.1 W At 60 DEG C
-
Output Type: Current Sourcing
-
Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports
-
Surge Current: 2 A For 10 MS/Point, Repeatable Every 2 SEC At 60 DEG C
-
Slot Width: 1
FEATURES
-
- Variety of voltage interface capabilities
- Isolated and nonisolated module types
- Point-level output fault states
- Direct-connect or rack-optimized communication
- Field-side diagnostics on select modules
- These modules have internal electronic fusing to prevent too much current from flowing through the module
- Standards: C/US UL listed, CSA certified, CE-ATEX, CE-EMC, CE-LVD, C-TICK, FM-US_HAZ, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR
|
|
|
|