Image is illustrative
|
Digital Output Termination Assembly ControlLogix, duplex, redundant I/O, 8-ch., 0.5A 18..32VDC, TS35, Allen-Bradley Code:
1715-TADOB8DE
Cena (indicative)
Manufacturer
:
Availability:
ask for dd
|
Weight:
0.372 kg/pc
|
Volume:
0.0041 m3/pc
|
|
|
|
|
Digital Output Termination Assembly ControlLogix, duplex, redundant I/O, 8-ch., 0.5A 18..32VDC, TS35, Allen-Bradley
DESCRIPTIONS
ControlLogix® Digital Output Termination Assembly, Type: Duplex, Redundant I/O, Number Of Channels: 8, Voltage Rating: 18 - 32 VDC, Current Rating: Backplane: 0.5 A Per Channel At 18 - 32 VDC, Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports, Type Tested At 500 VAC For 60 SEC, Enclosure: IP20, Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10V rms With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 18 - 16 AWG Solid/Stranded Copper Wire, Mounting: DIN Rail, Length: 1-5/8 IN, Width: 4-5/8 IN, Height: 6-1/2 IN, Temperature Rating: -25 To 70 DEG C, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G, Shock, Operating - DIN Rail Mount: 25 G, Panel Mount: 30 G, Shock, Non Operating - Installed: 30 G, Uninstalled: 50 G, Power Dissipation: System: 3 W, Field Loop: 0.17 W, Output Type: Digital, Surge Transient Immunity: Plus/Minus 1 KV line-line (DM) and Plus/Minus 2 KV line-earth (CM) on signal ports, Number Of Modules Supported: 2, Standard/Approvals: CE, C-tick, GOST, KC, GOST_R, KCC certified, ROSTECHNADZOR, C/US UL listed, Application: For redundant I/O
SPECIFICATIONS
-
Item Name: Digital Output Termination Assembly
-
Type: Duplex, Redundant I/O
-
Sub Brand: ControlLogix®
-
Number Of Channels: 8
-
Voltage Rating: 18 - 32 VDC
-
Current Rating: Backplane: 0.5 A Per Channel At 18 - 32 VDC
-
Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports, Type Tested At 500 VAC For 60 SEC
-
Enclosure: IP20
-
Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10V rms With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Connection Cables: 18 - 16 AWG Solid/Stranded Copper Wire
-
Mounting: DIN Rail
-
Length: 1-5/8 IN
-
Width: 4-5/8 IN
-
Height: 6-1/2 IN
-
Temperature Rating: -25 To 70 DEG C
-
Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G, Shock, Operating - DIN Rail Mount: 25 G, Panel Mount: 30 G, Shock, Non Operating - Installed: 30 G, Uninstalled: 50 G
-
Power Dissipation: System: 3 W, Field Loop: 0.17 W
-
Output Type: Digital
-
Surge Transient Immunity: Plus/Minus 1 KV line-line (DM) and Plus/Minus 2 KV line-earth (CM) on signal ports
FEATURES
- For the field I/O channels and, by the use of coding pegs and sockets, are matched to a specific I/O module
- Module keying can also be set in the RSLogix 5000 project
- Field connections are made at the terminal block connectors on the termination assembly
- 2 - On Signal Ports
- Fuses: 5 A for each supply
- Standards: CE, C-tick, GOST, KC, GOST_R, KCC certified, ROSTECHNADZOR, C/US UL listed
- Applications: For redundant I/O
|
|
File description
|
File type
|
Download link
|
|
|
|
Specification Sheet
|
PDF
|