Featured Products!
Ground Modular Terminal Block MT 1.5-PE, 50pcs/pck, Phoenix
Ground Modular Terminal Block MT 1.5-PE, 50pcs/pck, Phoenix



Digital Output Termination Assembly ControlLogix, duplex, redundant I/O, 8-ch., 0.5A 18..32VDC, TS35, Allen-Bradley
Image is illustrative
Digital Output Termination Assembly ControlLogix, duplex, redundant I/O, 8-ch., 0.5A 18..32VDC, TS35, Allen-Bradley
Code: 1715-TADOB8DE
Cena (indicative)
293,10 €  /pc
Manufacturer :
Availability:
ask for dd
Weight:
0.372 kg/pc
Volume:
0.0041 m3/pc
Quantity:
Plus sign Minus sign
 

 

Digital Output Termination Assembly ControlLogix, duplex, redundant I/O, 8-ch., 0.5A 18..32VDC, TS35, Allen-Bradley

DESCRIPTIONS

ControlLogix® Digital Output Termination Assembly, Type: Duplex, Redundant I/O, Number Of Channels: 8, Voltage Rating: 18 - 32 VDC, Current Rating: Backplane: 0.5 A Per Channel At 18 - 32 VDC, Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports, Type Tested At 500 VAC For 60 SEC, Enclosure: IP20, Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10V rms With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 18 - 16 AWG Solid/Stranded Copper Wire, Mounting: DIN Rail, Length: 1-5/8 IN, Width: 4-5/8 IN, Height: 6-1/2 IN, Temperature Rating: -25 To 70 DEG C, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G, Shock, Operating - DIN Rail Mount: 25 G, Panel Mount: 30 G, Shock, Non Operating - Installed: 30 G, Uninstalled: 50 G, Power Dissipation: System: 3 W, Field Loop: 0.17 W, Output Type: Digital, Surge Transient Immunity: Plus/Minus 1 KV line-line (DM) and Plus/Minus 2 KV line-earth (CM) on signal ports, Number Of Modules Supported: 2, Standard/Approvals: CE, C-tick, GOST, KC, GOST_R, KCC certified, ROSTECHNADZOR, C/US UL listed, Application: For redundant I/O

SPECIFICATIONS

  • Item Name: Digital Output Termination Assembly

  • Type: Duplex, Redundant I/O

  • Sub Brand: ControlLogix®

  • Number Of Channels: 8

  • Voltage Rating: 18 - 32 VDC

  • Current Rating: Backplane: 0.5 A Per Channel At 18 - 32 VDC

  • Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports, Type Tested At 500 VAC For 60 SEC

  • Enclosure: IP20

  • Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10V rms With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ

  • Connection Cables: 18 - 16 AWG Solid/Stranded Copper Wire

  • Mounting: DIN Rail

  • Length: 1-5/8 IN

  • Width: 4-5/8 IN

  • Height: 6-1/2 IN

  • Temperature Rating: -25 To 70 DEG C

  • Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G, Shock, Operating - DIN Rail Mount: 25 G, Panel Mount: 30 G, Shock, Non Operating - Installed: 30 G, Uninstalled: 50 G

  • Power Dissipation: System: 3 W, Field Loop: 0.17 W

  • Output Type: Digital

  • Surge Transient Immunity: Plus/Minus 1 KV line-line (DM) and Plus/Minus 2 KV line-earth (CM) on signal ports

FEATURES

  • For the field I/O channels and, by the use of coding pegs and sockets, are matched to a specific I/O module
  • Module keying can also be set in the RSLogix 5000 project
  • Field connections are made at the terminal block connectors on the termination assembly
  • 2 - On Signal Ports
  • Fuses: 5 A for each supply
  • Standards: CE, C-tick, GOST, KC, GOST_R, KCC certified, ROSTECHNADZOR, C/US UL listed
  • Applications: For redundant I/O
 
 