Note
|
NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.
|
Rated current at 40°C
|
4 A
|
Rated voltage
|
30 V AC
|
|
30 V DC
|
Number of positions
|
4
|
Insulation resistance
|
≥ 100 MΩ
|
Coding
|
A - standard
|
Standards/regulations
|
M8 connector IEC 61076-2-104
|
Signal type/category
|
Universal
|
Status display
|
No
|
Overvoltage category
|
III
|
Degree of pollution
|
3
|
Connection method
|
Screw connection
|
Conductor cross section
|
0.14 mm² ... 0.5 mm² (without ferrule)
|
|
0.08 mm² ... 0.5 mm² (with ferrule)
|
|
0.14 mm² ... 0.5 mm² (solid)
|
Conductor cross section AWG
|
26 ... 20 (without ferrule)
|
Insertion/withdrawal cycles
|
≥ 100
|
Torque
|
0.2 Nm (M8 knurl)
|
|
0.5 Nm (Connector with coupling sleeve)
|
|
0.3 Nm ... 0.4 Nm (Pressure screw for outer cable diameter 3 mm ... 4 mm)
|
|
0.8 Nm ... 1 Nm (Pressure screw in the case of external cable diameter 4 mm ... 5 mm)
|
|
0.1 Nm (Screw terminal blocks)
|
Assembly instructions
|
The wires can be connected both with ferrules (without insulation) and without ferrules.
|