Image is illustrative
|
Modbus TCP/IP Master/Slave Enhanced Communication Module in Remote Chassis, ProSoft Code:
MVI56E-MNETR
Cena (indicative)
Manufacturer
:
Availability:
ask for dd
|
Weight:
0.6 kg/pc
|
Volume:
0.0048 m3/pc
|
|
|
|
|
Modbus TCP/IP Master/Slave Enhanced Communication Module in Remote Chassis, ProSoft
DESCRIPTIONS
-
inRAx® Enhanced Modbus TCP/IP Client/Server Interface Module With Reduced Data Block, Communication Protocol: Ethernet, Modbus TCP/IP, Interface: Debug/Configuration/Application Ethernet Port, Power Supply: Backplane Current Load: 800 MA At 5 VDC, Connection Cables: CAT5, Mounting: DIN Rail, Temperature Rating: -25 To 70 DEG C Operating, Indicator: LED: Battery Status (ERR), Application Status (APP), Module Status (OK), Environmental Conditions: Storage Temperature: -40 To 85 DEG C, Shock: 30 G Operational, 50G Non-Operational, Vibration: 5 G From 10 To 150 HZ, Relative Humidity: 5 To 95% (Non-Condensing), Application: For ControlLogix processors
SPECIFICATIONS
-
-
Item Name: Enhanced Modbus TCP/IP Client/Server Interface Module With Reduced Data Block
-
Sub Brand: inRAx®
-
Communication Protocol: Ethernet, Modbus TCP/IP
-
Interface: Debug/Configuration/Application Ethernet Port
-
Power Supply: Backplane Current Load: 800 MA At 5 VDC
-
Connection Cables: CAT5
-
Mounting: DIN Rail
-
Temperature Rating: -25 To 70 DEG C Operating
-
Environmental Conditions: Storage Temperature: -40 To 85 DEG C, Shock: 30 G Operational, 50G Non-Operational, Vibration: 5 G From 10 To 150 HZ, Relative Humidity: 5 To 95% (Non-Condensing)
-
Indicator: LED: Battery Status (ERR), Application Status (APP), Module Status (OK)
FEATURES
-
- Module with Reduced Data Block allows Rockwell Automation ControlLogix processors to interface easily with Modbus TCP/IP-compatible devices, such as Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP/IP-compatible instruments and devices
- Reduced Input/Output (I/O) data image block size for transferring data between itself and a ControlLogix processor
- This makes it ideal for remote rack applications using ControlNet or EtherNet/IP process networks
- The module also works well for applications that require redundant ControlLogix processors
- Enhancements include local and remote configuration and diagnostics through the module's Ethernet port, CIPconnect technology for bridging though Rockwell Automation ControlNet and EtherNetIP networks, and an on-board web server for access to module documentation and sample program files
- Backward-Compatible: Upgrade earlier MVI56-MNETR modules without changing existing ladder logic programs or module configurations, Enhanced features and flexibility without incurring expensive reprogramming costs
- RSLogix 5000 Integrated: Module communication is integrated within RSLogix 5000 using a sample Add-On Instruction (AOI) or sample ladder logic file, No additional programming and/or configuration software are required
- Reduced Input/Output Image Size: Uses less bandwidth on process control networks like ControlNet or EtherNet/IP, Optimizes communication for more efficient remote rack installations, especially when using redundant ControlLogix processors
- Graphical User Interface Software: ProSoft Configuration Builder (PCB) provides online or offline configuration and online diagnostics using the high-speed Ethernet port, CIPconnect-enabled, allows remote configuration and diagnostic access across multiple bridged EtherNet/IP and ControlNet networks using Rockwell Automation 1756-ENxT and 1756-CNB network interface modules
- Web-enabled Ethernet port with Discovery Service: Module's built-in Ethernet port provides a web server for local access to documentation, module status, and firmware updates, ProSoft Discovery Service, a software utility to locate MVI56E modules on the network and assign a temporary IP address for easy configuration
- Applications: For ControlLogix processors
|
|
|
|
|