EMC Line Filter PowerFlex, 7.5kW 18A 3x480VAC, type L, long cable, Rockwell Automation
EMC Line Filter PowerFlex, 7.5kW 18A 3x480VAC, type L, long cable, Rockwell Automation



Modular Power Supply HDR, input 85..264VAC/120..370VDC, output 92W 3.83A 24..25.5VDC, LED, op. temp -30 to +70°C, W70mm, TS35/15/7.5, MaxPro
Image is illustrative
Modular Power Supply HDR, input 85..264VAC/120..370VDC, output 92W 3.83A 24..25.5VDC, LED, op. temp -30 to +70°C, W70mm, TS35/15/7.5, MaxPro
Code: HDR-100-24
Cena
39,70 €  /pc
Manufacturer :
Availability:
In Stock
Weight:
0.2835 kg/pc
Volume:
0.0004 m3/pc
Wholesale qty:
3pc
Quantity:
Plus sign Minus sign
 

 

HDR-100-24 - Product Specification

Specification Value
OUTPUT  
DC VOLTAGE 24V
RATED CURRENT 3.83A
CURRENT RANGE 0 ~ 3.83A
RATED POWER 92W
RlPPLE & NOlSE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE 24 ~ 25.5V
VOLTAGE TOLERANCE Note.3 ±1.0%
LlNE REGULATlON ±1.0%
LOAD REGULATlON ±1.0%
SETUP, RlSE TlME at full load 500ms, 60ms/230VAC 500ms, 60ms/115VAC
HOLD UP TlME (Typ.) 30ms/230VAC       12ms/115VAC at full load
lNPUT  
VOLTAGE RANGE 85 ~ 264VAC(277VAC operational )      120 ~ 370VDC(390VDC operational )
FREQUENCY RANGE 47 ~ 63Hz
EFFlClENCY (Typ.) 0.9
AC CURRENT (Typ.) 3A/115VAC       1.6A/230VAC
lNRUSH CURRENT (Typ.) COLD START 35A/115VAC | 70A/230VAC
PROTECTION  
OVERLOAD 102 ~ 110% rated output power
  Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed
  Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed
OVER VOLTAGE 30 ~ 36V
  Protection type : Shutdown o/p voltage, re-power on to recover
ENVlRONMENT  
WORKlNG TEMP. -30 ~ +70ºC
WORKlNG HUMlDlTY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMlDlTY -40 ~ +85ºC, 10 ~ 95% RH non-condensing
TEMP. COEFFlClENT ±0.03%/ºC (0 ~ 50ºC) RH non-condensing
VlBRATlON 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,Y, Z axes; Mounting: Compliance to lEC60068-2-6
OPERATlNG ALTlTUDE 2000 meters
OVERVOLTAGE CATEGORY ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY   
WiTHSTAND VOLTAGE l/P-O/P:4kVAC
lSOLATlON RESlSTANCE l/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH
OTHERS  
MTBF 3271.9k hrs min.    Telcordia SR-332(Bellcore); 856.5k hrs min.     MlL-HDBk-217F(25ºC)
DlMENSlON 70x90x54.5mm(W*H*D)
PACKlNG 0.27kg; 48pcs/13.74kg/0.96CUFT
NOTE  
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft).
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 
X
 
X