HDR-100-24 - Product Specification

Specification Value
OUTPUT  
DC VOLTAGE 24V
RATED CURRENT 3.83A
CURRENT RANGE 0 ~ 3.83A
RATED POWER 92W
RlPPLE & NOlSE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE 24 ~ 25.5V
VOLTAGE TOLERANCE Note.3 ±1.0%
LlNE REGULATlON ±1.0%
LOAD REGULATlON ±1.0%
SETUP, RlSE TlME at full load 500ms, 60ms/230VAC 500ms, 60ms/115VAC
HOLD UP TlME (Typ.) 30ms/230VAC       12ms/115VAC at full load
lNPUT  
VOLTAGE RANGE 85 ~ 264VAC(277VAC operational )      120 ~ 370VDC(390VDC operational )
FREQUENCY RANGE 47 ~ 63Hz
EFFlClENCY (Typ.) 0.9
AC CURRENT (Typ.) 3A/115VAC       1.6A/230VAC
lNRUSH CURRENT (Typ.) COLD START 35A/115VAC | 70A/230VAC
PROTECTION  
OVERLOAD 102 ~ 110% rated output power
  Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed
  Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed
OVER VOLTAGE 30 ~ 36V
  Protection type : Shutdown o/p voltage, re-power on to recover
ENVlRONMENT  
WORKlNG TEMP. -30 ~ +70ºC
WORKlNG HUMlDlTY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMlDlTY -40 ~ +85ºC, 10 ~ 95% RH non-condensing
TEMP. COEFFlClENT ±0.03%/ºC (0 ~ 50ºC) RH non-condensing
VlBRATlON 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,Y, Z axes; Mounting: Compliance to lEC60068-2-6
OPERATlNG ALTlTUDE 2000 meters
OVERVOLTAGE CATEGORY ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters
SAFETY   
WiTHSTAND VOLTAGE l/P-O/P:4kVAC
lSOLATlON RESlSTANCE l/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH
OTHERS  
MTBF 3271.9k hrs min.    Telcordia SR-332(Bellcore); 856.5k hrs min.     MlL-HDBk-217F(25ºC)
DlMENSlON 70x90x54.5mm(W*H*D)
PACKlNG 0.27kg; 48pcs/13.74kg/0.96CUFT
NOTE  
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft).
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 
X
 
X