| General information | 
| Product type designation | 
CPU 1212C AC/DC/relay | 
| Firmware version | 
V4.2 | 
| Engineering with | 
| ● Programming package | 
STEP 7 V14 or higher | 
| Supply voltage | 
| Rated value (AC) | 
 | 
| ● 120 V AC | 
Yes | 
| ● 230 V AC | 
Yes | 
| permissible range, lower limit (AC) | 
85 V | 
| permissible range, upper limit (AC) | 
264 V | 
| Line frequency | 
| ● permissible range, lower limit | 
47 Hz | 
| ● permissible range, upper limit | 
63 Hz | 
| Input current | 
| Current consumption (rated value) | 
80 mA at 120 V AC; 40 mA at 240 V AC | 
| Current consumption, max. | 
240 mA at 120 V AC; 120 mA at 240 V AC | 
| Inrush current, max. | 
20 A; at 264 V | 
| I²t | 
0.8 A²·s | 
| Output current | 
| for backplane bus (5 V DC), max. | 
1 000 mA; Max. 5 V DC for SM and CM | 
| Encoder supply | 
| 24 V encoder supply | 
| ● 24 V | 
20.4 to 28.8V | 
| Power loss | 
| Power loss, typ. | 
11 W | 
| Memory | 
| Work memory | 
| ● integrated | 
75 kbyte | 
| ● expandable | 
No | 
| Load memory | 
| ● integrated | 
2 Mbyte | 
| ● Plug-in (SIMATIC Memory Card), max. | 
with SIMATIC memory card | 
| Backup | 
| ● present | 
Yes | 
| ● maintenance-free | 
Yes | 
| ● without battery | 
Yes | 
| CPU processing times | 
| for bit operations, typ. | 
0.08 µs; / instruction | 
| for word operations, typ. | 
1.7 µs; / instruction | 
| for floating point arithmetic, typ. | 
2.3 µs; / instruction | 
| CPU-blocks | 
| Number of blocks (total) | 
DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used | 
| OB | 
| ● Number, max. | 
Limited only by RAM for code | 
| Data areas and their retentivity | 
| Retentive data area (incl. timers, counters, flags), max. | 
10 kbyte | 
| Flag | 
| ● Number, max. | 
4 kbyte; Size of bit memory address area | 
| Local data | 
| ● per priority class, max. | 
16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB | 
| Address area | 
| Process image | 
| ● Inputs, adjustable | 
1 kbyte | 
| ● Outputs, adjustable | 
1 kbyte | 
| Hardware configuration | 
| Number of modules per system, max. | 
3 comm. modules, 1 signal board, 2 signal modules | 
| Time of day | 
| Clock | 
| ● Hardware clock (real-time) | 
Yes | 
| ● Backup time | 
480 h; Typical | 
| ● Deviation per day, max. | 
±60 s/month at 25 °C | 
| Digital inputs | 
| Number of digital inputs | 
8; Integrated | 
| ● of which inputs usable for technological functions | 
4; HSC (High Speed Counting) | 
| Source/sink input | 
Yes | 
| Number of simultaneously controllable inputs | 
| all mounting positions | 
| — up to 40 °C, max. | 
8 | 
| Input voltage | 
| ● Rated value (DC) | 
24 V | 
| ● for signal "0" | 
5 V DC at 1 mA | 
| ● for signal "1" | 
15 V DC at 2.5 mA | 
| Input delay (for rated value of input voltage) | 
| for standard inputs | 
| — parameterizable | 
0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four | 
| — at "0" to "1", min. | 
0.2 ms | 
| — at "0" to "1", max. | 
12.8 ms | 
| for interrupt inputs | 
| — parameterizable | 
Yes | 
| for technological functions | 
| — parameterizable | 
Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz | 
| Cable length | 
| ● shielded, max. | 
500 m; 50 m for technological functions | 
| ● unshielded, max. | 
300 m; For technological functions: No | 
| Digital outputs | 
| Number of digital outputs | 
6; Relays | 
| Switching capacity of the outputs | 
| ● with resistive load, max. | 
2 A | 
| ● on lamp load, max. | 
30 W with DC, 200 W with AC | 
| Output delay with resistive load | 
| ● "0" to "1", max. | 
10 ms; max. | 
| ● "1" to "0", max. | 
10 ms; max. | 
| Relay outputs | 
| ● Number of operating cycles, max. | 
mechanically 10 million, at rated load voltage 100 000 | 
| Cable length | 
| ● shielded, max. | 
500 m | 
| ● unshielded, max. | 
150 m | 
| Analog inputs | 
| Number of analog inputs | 
2 | 
| Input ranges | 
| ● Voltage | 
Yes | 
| Input ranges (rated values), voltages | 
| ● 0 to +10 V | 
Yes | 
| ● Input resistance (0 to 10 V) | 
≥100k ohms | 
| Cable length | 
| ● shielded, max. | 
100 m; twisted and shielded | 
| Analog outputs | 
| Number of analog outputs | 
0 | 
| Analog value generation for the inputs | 
| Integration and conversion time/resolution per channel | 
| ● Resolution with overrange (bit including sign), max. | 
10 bit | 
| ● Integration time, parameterizable | 
Yes | 
| ● Conversion time (per channel) | 
625 µs | 
| Encoder | 
| Connectable encoders | 
| ● 2-wire sensor | 
Yes | 
| 1. Interface | 
| Interface type | 
PROFINET | 
| Physics | 
Ethernet | 
| Isolated | 
Yes | 
| automatic detection of transmission rate | 
Yes | 
| Autonegotiation | 
Yes | 
| Autocrossing | 
Yes | 
| Interface types | 
| ● Number of ports | 
1 | 
| ● integrated switch | 
No | 
| Protocols | 
| ● PROFINET IO Controller | 
Yes | 
| ● PROFINET IO Device | 
Yes | 
| ● SIMATIC communication | 
Yes | 
| ● Open IE communication | 
Yes | 
| ● Web server | 
Yes | 
| ● Media redundancy | 
No | 
| PROFINET IO Controller | 
| ● Transmission rate, max. | 
100 Mbit/s | 
| Services | 
| — PG/OP communication | 
Yes | 
| — S7 routing | 
Yes | 
| — Isochronous mode | 
No | 
| — Open IE communication | 
Yes | 
| — IRT | 
No | 
| — MRP | 
No | 
| — MRPD | 
No | 
| — PROFIenergy | 
No | 
| — Prioritized startup | 
Yes | 
| — Number of IO devices with prioritized startup, max. | 
16 | 
| — Number of connectable IO Devices, max. | 
16 | 
| — Number of connectable IO Devices for RT, max. | 
16 | 
| — of which in line, max. | 
16 | 
| — Activation/deactivation of IO Devices | 
Yes | 
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 
8 | 
| — Updating time | 
The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. | 
| PROFINET IO Device | 
| Services | 
| — PG/OP communication | 
Yes | 
| — S7 routing | 
Yes | 
| — Isochronous mode | 
No | 
| — Open IE communication | 
Yes | 
| — IRT | 
No | 
| — MRP | 
No | 
| — MRPD | 
No | 
| — PROFIenergy | 
Yes | 
| — Shared device | 
Yes | 
| — Number of IO Controllers with shared device, max. | 
2 | 
| Protocols | 
| Supports protocol for PROFINET IO | 
Yes | 
| PROFIBUS | 
Yes; CM 1243-5 required | 
| AS-Interface | 
Yes; CM 1243-2 required | 
| Protocols (Ethernet) | 
| ● TCP/IP | 
Yes | 
| ● DHCP | 
No | 
| ● SNMP | 
Yes | 
| ● DCP | 
Yes | 
| ● LLDP | 
Yes | 
| Open IE communication | 
| ● TCP/IP | 
Yes | 
| — Data length, max. | 
8 kbyte | 
| ● ISO-on-TCP (RFC1006) | 
Yes | 
| — Data length, max. | 
8 kbyte | 
| ● UDP | 
Yes | 
| — Data length, max. | 
1 472 byte | 
| Web server | 
| ● supported | 
Yes | 
| ● User-defined websites | 
Yes | 
| Further protocols | 
| ● MODBUS | 
Yes | 
| Communication functions | 
| S7 communication | 
| ● supported | 
Yes | 
| ● as server | 
Yes | 
| ● as client | 
Yes | 
| ● User data per job, max. | 
See online help (S7 communication, user data size) | 
| Number of connections | 
| ● overall | 
16; dynamically | 
| Test commissioning functions | 
| Status/control | 
| ● Status/control variable | 
Yes | 
| ● Variables | 
Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | 
| Forcing | 
| ● Forcing | 
Yes | 
| Diagnostic buffer | 
| ● present | 
Yes | 
| Traces | 
| ● Number of configurable Traces | 
2 | 
| ● Memory size per trace, max. | 
512 kbyte | 
| Interrupts/diagnostics/status information | 
| Diagnostics indication LED | 
| ● RUN/STOP LED | 
Yes | 
| ● ERROR LED | 
Yes | 
| ● MAINT LED | 
Yes | 
| Integrated Functions | 
| Number of counters | 
4 | 
| Counting frequency (counter) max. | 
100 kHz | 
| Frequency measurement | 
Yes | 
| controlled positioning | 
Yes | 
| Number of position-controlled positioning axes, max. | 
8 | 
| Number of positioning axes via pulse-direction interface | 
Up to 4 with SB 1222 | 
| PID controller | 
Yes | 
| Number of alarm inputs | 
4 | 
| Potential separation | 
| Potential separation digital inputs | 
| ● Potential separation digital inputs | 
500V AC for 1 minute | 
| ● between the channels, in groups of | 
1 | 
| Potential separation digital outputs | 
| ● Potential separation digital outputs | 
Relays | 
| ● between the channels | 
No | 
| ● between the channels, in groups of | 
2 | 
| EMC | 
| Interference immunity against discharge of static electricity | 
| ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | 
Yes | 
| — Test voltage at air discharge | 
8 kV | 
| — Test voltage at contact discharge | 
6 kV | 
| Interference immunity to cable-borne interference | 
| ● Interference immunity on supply lines acc. to IEC 61000-4-4 | 
Yes | 
| ● Interference immunity on signal cables acc. to IEC 61000-4-4 | 
Yes | 
| Interference immunity against voltage surge | 
| ● on the supply lines acc. to IEC 61000-4-5 | 
Yes | 
| Interference immunity against conducted variable disturbance induced by high-frequency fields | 
| ● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | 
Yes | 
| Emission of radio interference acc. to EN 55 011 | 
| ● Limit class A, for use in industrial areas | 
Yes; Group 1 | 
| ● Limit class B, for use in residential areas | 
Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | 
| Degree and class of protection | 
| Degree of protection acc. to EN 60529 | 
 | 
| ● IP20 | 
Yes | 
| Standards, approvals, certificates | 
| CE mark | 
Yes | 
| UL approval | 
Yes | 
| cULus | 
Yes | 
| FM approval | 
Yes | 
| RCM (formerly C-TICK) | 
Yes | 
| KC approval | 
Yes | 
| Marine approval | 
Yes | 
| Ambient conditions | 
| Free fall | 
| ● Fall height, max. | 
0.3 m; five times, in product package | 
| Ambient temperature during operation | 
| ● min. | 
-20 °C | 
| ● max. | 
60 °C; Number of simultaneously activated inputs or outputs 4 or 3 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 8 or 6 at 55 °C horizontal or 45 °C vertical | 
| ● horizontal installation, min. | 
-20 °C | 
| ● horizontal installation, max. | 
60 °C | 
| ● vertical installation, min. | 
-20 °C | 
| ● vertical installation, max. | 
50 °C | 
| Ambient temperature during storage/transportation | 
| ● min. | 
-40 °C | 
| ● max. | 
70 °C | 
| Air pressure acc. to IEC 60068-2-13 | 
| ● Operation, min. | 
795 hPa | 
| ● Operation, max. | 
1 080 hPa | 
| ● Storage/transport, min. | 
660 hPa | 
| ● Storage/transport, max. | 
1 080 hPa | 
| Altitude during operation relating to sea level | 
| ● Installation altitude, min. | 
-1 000 m | 
| ● Installation altitude, max. | 
2 000 m | 
| Relative humidity | 
| ● Operation, max. | 
95 %; no condensation | 
| Vibrations | 
| ● Vibration resistance during operation acc. to IEC 60068-2-6 | 
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail | 
| ● Operation, tested according to IEC 60068-2-6 | 
Yes | 
| Shock testing | 
| ● tested according to IEC 60068-2-27 | 
Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | 
| Pollutant concentrations | 
| ● SO2 at RH < 60% without condensation | 
S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | 
| Configuration | 
| Programming | 
| Programming language | 
| — LAD | 
Yes | 
| — FBD | 
Yes | 
| — SCL | 
Yes | 
| Know-how protection | 
| ● User program protection/password protection | 
Yes | 
| ● Copy protection | 
Yes | 
| ● Block protection | 
Yes | 
| Access protection | 
| ● Protection level: Write protection | 
Yes | 
| ● Protection level: Read/write protection | 
Yes | 
| ● Protection level: Complete protection | 
Yes | 
| Cycle time monitoring | 
| ● adjustable | 
Yes | 
| Dimensions | 
| Width | 
90 mm | 
| Height | 
100 mm | 
| Depth | 
75 mm | 
| Weights | 
| Weight, approx. | 
425 g | 
| last modified: | 
11/10/2018 |