| General information | 
| Product type designation | CPU 1211C DC/DC/DC | 
| Firmware version | V4.2 | 
| Engineering with | 
| ● Programming package | STEP 7 V14 or higher | 
| Supply voltage | 
| Rated value (DC) |  | 
| ● 24 V DC | Yes | 
| permissible range, lower limit (DC) | 20.4 V | 
| permissible range, upper limit (DC) | 28.8 V | 
| Reverse polarity protection | Yes | 
| Load voltage L+ | 
| ● Rated value (DC) | 24 V | 
| ● permissible range, lower limit (DC) | 20.4 V | 
| ● permissible range, upper limit (DC) | 28.8 V | 
| Input current | 
| Current consumption (rated value) | 300 mA; CPU only | 
| Current consumption, max. | 900 mA; CPU with all expansion modules | 
| Inrush current, max. | 12 A; at 28.8 V DC | 
| I²t | 0.5 A²·s | 
| Output current | 
| for backplane bus (5 V DC), max. | 750 mA; Max. 5 V DC for CM | 
| Encoder supply | 
| 24 V encoder supply | 
| ● 24 V | L+ minus 4 V DC min. | 
| Power loss | 
| Power loss, typ. | 8 W | 
| Memory | 
| Work memory | 
| ● integrated | 50 kbyte | 
| ● expandable | No | 
| Load memory | 
| ● integrated | 1 Mbyte | 
| ● Plug-in (SIMATIC Memory Card), max. | with SIMATIC memory card | 
| Backup | 
| ● present | Yes | 
| ● maintenance-free | Yes | 
| ● without battery | Yes | 
| CPU processing times | 
| for bit operations, typ. | 0.08 µs; / instruction | 
| for word operations, typ. | 1.7 µs; / instruction | 
| for floating point arithmetic, typ. | 2.3 µs; / instruction | 
| CPU-blocks | 
| Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used | 
| OB | 
| ● Number, max. | Limited only by RAM for code | 
| Data areas and their retentivity | 
| Retentive data area (incl. timers, counters, flags), max. | 10 kbyte | 
| Flag | 
| ● Number, max. | 4 kbyte; Size of bit memory address area | 
| Local data | 
| ● per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB | 
| Address area | 
| Process image | 
| ● Inputs, adjustable | 1 kbyte | 
| ● Outputs, adjustable | 1 kbyte | 
| Hardware configuration | 
| Number of modules per system, max. | 3 communication modules, 1 signal board | 
| Time of day | 
| Clock | 
| ● Hardware clock (real-time) | Yes | 
| ● Backup time | 480 h; Typical | 
| ● Deviation per day, max. | ±60 s/month at 25 °C | 
| Digital inputs | 
| Number of digital inputs | 6; Integrated | 
| ● of which inputs usable for technological functions | 3; HSC (High Speed Counting) | 
| Source/sink input | Yes | 
| Number of simultaneously controllable inputs | 
| all mounting positions | 
| — up to 40 °C, max. | 6 | 
| Input voltage | 
| ● Rated value (DC) | 24 V | 
| ● for signal "0" | 5 V DC at 1 mA | 
| ● for signal "1" | 15 V DC at 2.5 mA | 
| Input current | 
| ● for signal "1", typ. | 4 mA; nominal | 
| Input delay (for rated value of input voltage) | 
| for standard inputs | 
| — parameterizable | 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms | 
| — at "0" to "1", min. | 0.2 ms | 
| — at "0" to "1", max. | 12.8 ms | 
| for interrupt inputs | 
| — parameterizable | Yes | 
| for technological functions | 
| — parameterizable | Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz | 
| Cable length | 
| ● shielded, max. | 500 m; 50 m for technological functions | 
| ● unshielded, max. | 300 m; For technological functions: No | 
| Digital outputs | 
| Number of digital outputs | 4 | 
| ● of which high-speed outputs | 4; 100 kHz Pulse Train Output | 
| Limitation of inductive shutdown voltage to | L+ (-48 V) | 
| Switching capacity of the outputs | 
| ● with resistive load, max. | 0.5 A | 
| ● on lamp load, max. | 5 W | 
| Output voltage | 
| ● for signal "0", max. | 0.1 V; with 10 kOhm load | 
| ● for signal "1", min. | 20 V | 
| Output current | 
| ● for signal "1" rated value | 0.5 A | 
| ● for signal "0" residual current, max. | 0.1 mA | 
| Output delay with resistive load | 
| ● "0" to "1", max. | 1 µs | 
| ● "1" to "0", max. | 5 µs | 
| Switching frequency | 
| ● of the pulse outputs, with resistive load, max. | 100 kHz | 
| Cable length | 
| ● shielded, max. | 500 m | 
| ● unshielded, max. | 150 m | 
| Analog inputs | 
| Number of analog inputs | 2 | 
| Input ranges | 
| ● Voltage | Yes | 
| Input ranges (rated values), voltages | 
| ● 0 to +10 V | Yes | 
| ● Input resistance (0 to 10 V) | ≥100k ohms | 
| Cable length | 
| ● shielded, max. | 100 m; twisted and shielded | 
| Analog outputs | 
| Number of analog outputs | 0 | 
| Analog value generation for the inputs | 
| Integration and conversion time/resolution per channel | 
| ● Resolution with overrange (bit including sign), max. | 10 bit | 
| ● Integration time, parameterizable | Yes | 
| ● Conversion time (per channel) | 625 µs | 
| Encoder | 
| Connectable encoders | 
| ● 2-wire sensor | Yes | 
| 1. Interface | 
| Interface type | PROFINET | 
| Physics | Ethernet | 
| Isolated | Yes | 
| automatic detection of transmission rate | Yes | 
| Autonegotiation | Yes | 
| Autocrossing | Yes | 
| Interface types | 
| ● Number of ports | 1 | 
| ● integrated switch | No | 
| Protocols | 
| ● PROFINET IO Controller | Yes | 
| ● PROFINET IO Device | Yes | 
| ● SIMATIC communication | Yes | 
| ● Open IE communication | Yes | 
| ● Web server | Yes | 
| ● Media redundancy | No | 
| PROFINET IO Controller | 
| ● Transmission rate, max. | 100 Mbit/s | 
| Services | 
| — PG/OP communication | Yes | 
| — S7 routing | Yes | 
| — Isochronous mode | No | 
| — Open IE communication | Yes | 
| — IRT | No | 
| — MRP | No | 
| — MRPD | No | 
| — PROFIenergy | No | 
| — Prioritized startup | Yes | 
| — Number of IO devices with prioritized startup, max. | 16 | 
| — Number of connectable IO Devices, max. | 16 | 
| — Number of connectable IO Devices for RT, max. | 16 | 
| — of which in line, max. | 16 | 
| — Activation/deactivation of IO Devices | Yes | 
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 | 
| — Updating time | The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. | 
| PROFINET IO Device | 
| Services | 
| — PG/OP communication | Yes | 
| — S7 routing | Yes | 
| — Isochronous mode | No | 
| — Open IE communication | Yes | 
| — IRT | No | 
| — MRP | No | 
| — MRPD | No | 
| — PROFIenergy | Yes | 
| — Shared device | Yes | 
| — Number of IO Controllers with shared device, max. | 2 | 
| Protocols | 
| Supports protocol for PROFINET IO | Yes | 
| PROFIBUS | Yes; CM 1243-5 required | 
| AS-Interface | Yes; CM 1243-2 required | 
| Protocols (Ethernet) | 
| ● TCP/IP | Yes | 
| ● DHCP | No | 
| ● SNMP | Yes | 
| ● DCP | Yes | 
| ● LLDP | Yes | 
| Open IE communication | 
| ● TCP/IP | Yes | 
| — Data length, max. | 8 kbyte | 
| — several passive connections per port, supported | Yes | 
| ● ISO-on-TCP (RFC1006) | Yes | 
| — Data length, max. | 8 kbyte | 
| ● UDP | Yes | 
| — Data length, max. | 1 472 byte | 
| Web server | 
| ● supported | Yes | 
| ● User-defined websites | Yes | 
| Further protocols | 
| ● MODBUS | Yes | 
| Communication functions | 
| S7 communication | 
| ● supported | Yes | 
| ● as server | Yes | 
| ● as client | Yes | 
| ● User data per job, max. | See online help (S7 communication, user data size) | 
| Number of connections | 
| ● overall | 16; dynamically | 
| Test commissioning functions | 
| Status/control | 
| ● Status/control variable | Yes | 
| ● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | 
| Forcing | 
| ● Forcing | Yes | 
| Diagnostic buffer | 
| ● present | Yes | 
| Traces | 
| ● Number of configurable Traces | 2 | 
| ● Memory size per trace, max. | 512 kbyte | 
| Interrupts/diagnostics/status information | 
| Diagnostics indication LED | 
| ● RUN/STOP LED | Yes | 
| ● ERROR LED | Yes | 
| ● MAINT LED | Yes | 
| Integrated Functions | 
| Number of counters | 6 | 
| Counting frequency (counter) max. | 100 kHz | 
| Frequency measurement | Yes | 
| controlled positioning | Yes | 
| Number of position-controlled positioning axes, max. | 8 | 
| Number of positioning axes via pulse-direction interface | 4; With integrated outputs | 
| PID controller | Yes | 
| Number of alarm inputs | 4 | 
| Number of pulse outputs | 4 | 
| Limit frequency (pulse) | 100 kHz | 
| Potential separation | 
| Potential separation digital inputs | 
| ● Potential separation digital inputs | No | 
| ● between the channels, in groups of | 1 | 
| Potential separation digital outputs | 
| ● Potential separation digital outputs | Yes | 
| ● between the channels | No | 
| ● between the channels, in groups of | 1 | 
| EMC | 
| Interference immunity against discharge of static electricity | 
| ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes | 
| — Test voltage at air discharge | 8 kV | 
| — Test voltage at contact discharge | 6 kV | 
| Interference immunity to cable-borne interference | 
| ● Interference immunity on supply lines acc. to IEC 61000-4-4 | Yes | 
| ● Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes | 
| Interference immunity against voltage surge | 
| ● on the supply lines acc. to IEC 61000-4-5 | Yes | 
| Interference immunity against conducted variable disturbance induced by high-frequency fields | 
| ● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes | 
| Emission of radio interference acc. to EN 55 011 | 
| ● Limit class A, for use in industrial areas | Yes; Group 1 | 
| ● Limit class B, for use in residential areas | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | 
| Degree and class of protection | 
| Degree of protection acc. to EN 60529 |  | 
| ● IP20 | Yes | 
| Standards, approvals, certificates | 
| CE mark | Yes | 
| UL approval | Yes | 
| cULus | Yes | 
| FM approval | Yes | 
| RCM (formerly C-TICK) | Yes | 
| KC approval | Yes | 
| Marine approval | Yes | 
| Ambient conditions | 
| Free fall | 
| ● Fall height, max. | 0.3 m; five times, in product package | 
| Ambient temperature during operation | 
| ● min. | -20 °C | 
| ● max. | 60 °C | 
| ● horizontal installation, min. | -20 °C | 
| ● horizontal installation, max. | 60 °C | 
| ● vertical installation, min. | -20 °C | 
| ● vertical installation, max. | 50 °C | 
| Ambient temperature during storage/transportation | 
| ● min. | -40 °C | 
| ● max. | 70 °C | 
| Air pressure acc. to IEC 60068-2-13 | 
| ● Operation, min. | 795 hPa | 
| ● Operation, max. | 1 080 hPa | 
| ● Storage/transport, min. | 660 hPa | 
| ● Storage/transport, max. | 1 080 hPa | 
| Altitude during operation relating to sea level | 
| ● Installation altitude, min. | -1 000 m | 
| ● Installation altitude, max. | 2 000 m | 
| Relative humidity | 
| ● Operation, max. | 95 %; no condensation | 
| Vibrations | 
| ● Vibration resistance during operation acc. to IEC 60068-2-6 | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail | 
| ● Operation, tested according to IEC 60068-2-6 | Yes | 
| Shock testing | 
| ● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | 
| Pollutant concentrations | 
| ● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | 
| Configuration | 
| Programming | 
| Programming language | 
| — LAD | Yes | 
| — FBD | Yes | 
| — SCL | Yes | 
| Know-how protection | 
| ● User program protection/password protection | Yes | 
| ● Copy protection | Yes | 
| ● Block protection | Yes | 
| Access protection | 
| ● Protection level: Write protection | Yes | 
| ● Protection level: Read/write protection | Yes | 
| ● Protection level: Complete protection | Yes | 
| Cycle time monitoring | 
| ● adjustable | Yes | 
| Dimensions | 
| Width | 90 mm | 
| Height | 100 mm | 
| Depth | 75 mm | 
| Weights | 
| Weight, approx. | 370 g | 
| last modified: | 11/10/2018 |