Simatic DP, Electronics Module ET 200S, 2/4AI RTD, W15 mm, 15bit+sign Pt100/Pt100 KL/NI100/NI100 KL/150Ω/300Ω/600Ω, cycle time 110ms/ch., SF LED (group fault), Siemens
Image is illustrative
Simatic DP, Electronics Module ET 200S, 2/4AI RTD, W15 mm, 15bit+sign Pt100/Pt100 KL/NI100/NI100 KL/150Ω/300Ω/600Ω, cycle time 110ms/ch., SF LED (group fault), Siemens
Code: 6ES7134-4JB51-0AB0
Cena (indicative)
154,80 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.0452 kg/pc
Volume:
0.0001 m3/pc
Quantity:
Plus sign Minus sign
 

 

Simatic DP, electronic module ET200S, 2/4AI RTD, W15mm, 15bit +sign, PT100/PT100 KL/NI100/NI100 KL, 150?/300?/600?, cycle time 110ms/ch., LED SF (group fault), Siemens

Supply voltage
Load voltage L+
● Rated value (DC) 24 V; From power module
● Reverse polarity protection Yes
Input current
from load voltage L+ (without load), max. 30 mA
from backplane bus 3.3 V DC, max. 10 mA
Output voltage
Power supply to the transmitters
● present Yes
● short-circuit proof Yes
Power loss
Power loss, typ. 0.6 W
Address area
Address space per module
● Address space per module, max. 8 byte
Analog inputs
Number of analog inputs 4; 2 for 3 or 4-wire connection
permissible input voltage for voltage input (destruction limit), max. 9 V
Constant measurement current for resistance-type transmitter, typ. 1.67 mA
Cycle time (all channels) max. Number of active channels per module x basic conversion time
Technical unit for temperature measurement adjustable No
Input ranges
● Voltage No
● Current No
● Thermocouple No
● Resistance thermometer Yes
● Resistance Yes
Input ranges (rated values), resistance thermometer
● Ni 100 Yes; Standard/climate
● Input resistance (Ni 100) 2 000 kΩ
● Pt 100 Yes; Standard/climate
● Input resistance (Pt 100) 2 000 kΩ
Input ranges (rated values), resistors
● 0 to 150 ohms Yes
● Input resistance (0 to 150 ohms) 2 000 kΩ
● 0 to 300 ohms Yes
● Input resistance (0 to 300 ohms) 2 000 kΩ
● 0 to 600 ohms Yes
● Input resistance (0 to 600 ohms) 2 000 kΩ
Characteristic linearization
● parameterizable Yes; for Pt100, Ni100
— for resistance thermometer Pt100 (standard, climatic range), Ni100 (standard, climatic range)
Cable length
● shielded, max. 200 m
Analog value generation for the inputs
Measurement principle integrating
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 16 bit; 150 ohms: 14 bits; 300, 600 ohms: 15 bits, Pt100, Ni100: 16 bits
● Integration time, parameterizable Yes
● Integration time (ms) 16,7 / 20 ms
● Interference voltage suppression for interference frequency f1 in Hz 50 / 60 Hz
● Conversion time (per channel) 66 / 80 ms; additional conversion time for diagnostic wire break test
Smoothing of measured values
● parameterizable Yes; In four stages by means of digital filtering
● Step: None Yes; 1 x cycle time
● Step: low Yes; 4 x cycle time
● Step: Medium Yes; 32 x cycle time
● Step: High Yes; 64 x cycle time
Encoder
Connection of signal encoders
● for resistance measurement with two-wire connection Yes
● for resistance measurement with three-wire connection Yes
● for resistance measurement with four-wire connection Yes
Errors/accuracies
Linearity error (relative to input range), (+/-) 0.01 %
Temperature error (relative to input range), (+/-) 0.005 %/K
Crosstalk between the inputs, min. -50 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.05 %
Operational error limit in overall temperature range
● Resistance thermometer, relative to input range, (+/-) 0.6 %
Basic error limit (operational limit at 25 °C)
● Resistance thermometer, relative to input range, (+/-) 0.4 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min. 70 dB
● Common mode interference (USS < 2.5 V) , min. 90 dB
Isochronous mode
Isochronous operation (application synchronized up to terminal) No
Interrupts/diagnostics/status information
Diagnostic messages
● Wire-break Yes
● Group error Yes
● Overflow/underflow Yes
Diagnostics indication LED
● Group error SF (red) Yes
Parameter
Diagnostics wire break Disable / enable
Measurement type/range deactivated/150 ohms/; 300 ohms/600 ohms/ Pt100 climatic/ Pt100 standard; Ni100 standard / Ni100 climatic, 2, 3 or 4-wire
Group diagnostics Disable / enable
Overflow/underflow Disable / enable
Potential separation
Potential separation analog inputs
● between the channels No
● between the channels and backplane bus Yes
● Between the channels and load voltage L+ Yes
Permissible potential difference
between MANA and M internally (UISO) 75 V DC/60 V AC
Isolation
Isolation tested with 500 V DC
Dimensions
Width 15 mm
Height 81 mm
Depth 52 mm
Weights
Weight 40 g