Controller Safedge Guardmaster, 24VAC/VDC, 2NO safety, 1NC aux., auto/man reset, PC, TS35, Allen-Bradley Code:
440F-C251D
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.553 kg/pc
|
Volume:
0.0018 m3/pc
|
|
|
|
|
Controller Safedge Guardmaster, 24VAC/VDC, 2NO safety, 1NC aux., auto/man reset, PC, TS35, Allen-Bradley
DESCRIPTIONS
-
Safedge™ Guardmaster® Controller, Size: 4.72 IN Depth, Mounting: Surface Mount 35 MM/DIN Rail, Temperature Rating: -10 To 55 DEG C, Response Time: 13 MS, Enclosure: IP40, NEMA 1, Environmental Conditions: Shock: 10 G, Coil Voltage: 24 VAC/VDC, 110/230 VAC, Reset Type: Automatic/Manual, Housing Material: Polycarbonate, Withstand Voltage: 2500 V, Operating Cycles: Electrical Life: 0.3 - 0.1 M At 220 VAC/4 A, 0.6 - 0.5 M At 220 VAC/1.7 A, 1 M At 30 VDC/2 A, 2 M At 10 VDC/0.01 A, Switching Current: 10 MA At 10 V, Conductor Size: 10 AWG Stranded, 10 AWG Solid, Contact Configuration: 2NO Safety, 1NC Auxiliary, Power Rating: Less Than 6 VA, Terminal Type: Fixed
SPECIFICATIONS
-
-
Item Name: Controller
-
Sub Brand: Safedge™ Guardmaster®
-
Size: 4.72 IN Depth
-
Mounting: Surface Mount 35 MM/DIN Rail
-
Temperature Rating: -10 To 55 DEG C
-
Response Time: 13 MS
-
Enclosure: IP40, NEMA 1
-
Environmental Conditions: Shock: 10 G
-
Coil Voltage: 24 VAC/VDC, 110/230 VAC
-
Power Rating: Less Than 6 VA
-
Reset Type: Automatic/Manual
-
Housing Material: Polycarbonate
-
Conductor Size: 10 AWG Stranded, 10 AWG Solid
-
Withstand Voltage: 2500 V
-
Operating Cycles: Electrical Life: 0.3 - 0.1 M At 220 VAC/4 A, 0.6 - 0.5 M At 220 VAC/1.7 A, 1 M At 30 VDC/2 A, 2 M At 10 VDC/0.01 A
-
Switching Current: 10 MA At 10 V
-
Contact Configuration: 2NO Safety, 1NC Auxiliary
-
Terminal Type: Fixed
FEATURES
-
The Safedge controllers are designed to operate with the Safedge profiles. The controller continuously monitors the profile for actuation and generates an output signal when the profile is depressed. The Safedge controller provides a low voltage to the profile. When the profile is pressed, the controller detects a change in resistance and turns off its output relays. When pressure is released from the profile, the output relays of the controller return to an on state. The controller has redundant voltage free positively-guided output relays, which can be used to interface with a machine control system. - Output monitoring
- LED indicators for RUN, STOP, and OPEN
- Standards: EN1760-2, EN954-1, ISO 13849-1, AS 4024.5, EN 954-1, ANSI B11.19, cat. 3 per EN 954-1, CE marked
|
|
|
|