Feed-through Terminal WDU 35 BL, 35mm² 125A 1000V, Weidmüller, blue
Feed-through Terminal WDU 35 BL, 35mm² 125A 1000V, Weidmüller, blue



High-current Terminal UKH 150, 3pcs/pck, Phoenix
Image is illustrative
High-current Terminal UKH 150, 3pcs/pck, Phoenix
Code: 3010110
Cena
108,30 €  /pk
Package 3pc, unit price 36.1EUR/pc
Manufacturer :
Availability:
21 days
Weight:
0.3655 kg/pc
Volume:
0.0016 m3/pc
Quantity:
Plus sign Minus sign
 

 

High-current Terminal UKH 150, 3pcs/pck, Phoenix

General

Number of rows 1
Number of connections 2
Potentials 1
Nominal cross section 150 mm²
Color gray
Insulating material PA
Flammability rating according to UL 94 V0
Mounting type NS 35/15
Rated surge voltage 8 kV
Degree of pollution 3
Overvoltage category III
Insulating material group I
Maximum load current 309 A (with 150 mm² conductor cross section)
Nominal current IN 309 A
Nominal voltage UN 1000 V
Open side panel No
Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protection guaranteed
Result of surge voltage test Test passed
Surge voltage test setpoint 9.8 kV
Result of power-frequency withstand voltage test Test passed
Power frequency withstand voltage setpoint 2.2 kV
Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
Result of flexion and pull-out test Test passed
Bending test rotation speed 10 rpm
Bending test turns 135
Bending test conductor cross section/weight 35 mm² / 6.8 kg
50 mm² / 9.5 kg
Tensile test result Test passed
Conductor cross section tensile test 35 mm²
Tractive force setpoint 190 N
Conductor cross section tensile test 50 mm²
Tractive force setpoint 236 N
Conductor cross section tensile test 150 mm²
Tractive force setpoint 427 N
Result of tight fit on support Test passed
Tight fit on carrier NS 32/NS 35
Result of voltage-drop test Test passed
Result of temperature-rise test Test passed
Short circuit stability result Test passed
Conductor cross section short circuit testing 150 mm²
Short-time current 18 kA
Result of thermal test Test passed
Proof of thermal characteristics (needle flame) effective duration 30 s
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
Static insulating material application in cold -60 °C
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3

Dimensions

Width 31 mm
Length 100 mm
Height 107.3 mm
Height NS 35/15 118.5 mm
Height NS 32 116 mm

Connection data

Note Screws with hexagonal socket
Connection method Screw connection
Screw thread M10
Stripping length 40 mm
Tightening torque, min 25 Nm
Tightening torque max 30 Nm
Connection in acc. with standard IEC 60947-7-1
Note Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
Conductor cross section solid min. 35 mm²
Conductor cross section solid max. 150 mm²
Conductor cross section AWG min. 2
Conductor cross section AWG max. 300 kcmil
Conductor cross section flexible min. 50 mm²
Conductor cross section flexible max. 150 mm²
Min. AWG conductor cross section, flexible 1/0
Max. AWG conductor cross section, flexible 300 kcmil
Conductor cross section flexible, with ferrule without plastic sleeve min. 50 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 150 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. 50 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max. 150 mm²
Cross section with insertion bridge, solid max. 150 mm²
Cross section with insertion bridge, stranded max. 120 mm²
2 conductors with same cross section, solid min. 25 mm²
2 conductors with same cross section, solid max. 50 mm²
2 conductors with same cross section, stranded min. 35 mm²
2 conductors with same cross section, stranded max. 50 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 25 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 50 mm²
Internal cylindrical gage B14

Ambient conditions

Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 125°C)
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Permissible humidity (storage/transport) 30 % ... 70 %
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C

Standards and Regulations

Connection in acc. with standard CSA
IEC 60947-7-1
Flammability rating according to UL 94 V0

Environmental Product Compliance

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

ECLASS

ECLASS 10.0.1 27141120
ECLASS 11.0 27141120
ECLASS 4.0 27141100
ECLASS 4.1 27141100
ECLASS 5.0 27141100
ECLASS 5.1 27141100
ECLASS 6.0 27141100
ECLASS 7.0 27141120
ECLASS 9.0 27141120

ETIM

ETIM 2.0 EC000897
ETIM 3.0 EC000897
ETIM 4.0 EC000897
ETIM 6.0 EC000897
ETIM 7.0 EC000897

UNSPSC

UNSPSC 6.01 30211811
UNSPSC 7.0901 39121410
UNSPSC 11 39121410
UNSPSC 12.01 39121410
UNSPSC 13.2 39121410
UNSPSC 18.0 39121410
UNSPSC 19.0 39121410
UNSPSC 20.0 39121410
UNSPSC 21.0 39121410
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 
X
 
X