Image is illustrative
|
High-current Terminal UKH 150, 3pcs/pck, Phoenix Code:
3010110
Cena
108,30 €
/pk
Package 3pc, unit price
36.1EUR/pc
Manufacturer
:
Availability:
21 days
|
Weight:
0.3655 kg/pc
|
Volume:
0.0016 m3/pc
|
|
|
|
|
High-current Terminal UKH 150, 3pcs/pck, PhoenixGeneral
Number of rows
|
1
|
Number of connections
|
2
|
Potentials
|
1
|
Nominal cross section
|
150 mm²
|
Color
|
gray
|
Insulating material
|
PA
|
Flammability rating according to UL 94
|
V0
|
Mounting type
|
NS 35/15
|
Rated surge voltage
|
8 kV
|
Degree of pollution
|
3
|
Overvoltage category
|
III
|
Insulating material group
|
I
|
Maximum load current
|
309 A (with 150 mm² conductor cross section)
|
Nominal current IN
|
309 A
|
Nominal voltage UN
|
1000 V
|
Open side panel
|
No
|
Shock protection test specification
|
DIN EN 50274 (VDE 0660-514):2002-11
|
Back of the hand protection
|
guaranteed
|
Result of surge voltage test
|
Test passed
|
Surge voltage test setpoint
|
9.8 kV
|
Result of power-frequency withstand voltage test
|
Test passed
|
Power frequency withstand voltage setpoint
|
2.2 kV
|
Result of the test for mechanical stability of terminal points (5 x conductor connection)
|
Test passed
|
Result of flexion and pull-out test
|
Test passed
|
Bending test rotation speed
|
10 rpm
|
Bending test turns
|
135
|
Bending test conductor cross section/weight
|
35 mm² / 6.8 kg
|
|
50 mm² / 9.5 kg
|
Tensile test result
|
Test passed
|
Conductor cross section tensile test
|
35 mm²
|
Tractive force setpoint
|
190 N
|
Conductor cross section tensile test
|
50 mm²
|
Tractive force setpoint
|
236 N
|
Conductor cross section tensile test
|
150 mm²
|
Tractive force setpoint
|
427 N
|
Result of tight fit on support
|
Test passed
|
Tight fit on carrier
|
NS 32/NS 35
|
Result of voltage-drop test
|
Test passed
|
Result of temperature-rise test
|
Test passed
|
Short circuit stability result
|
Test passed
|
Conductor cross section short circuit testing
|
150 mm²
|
Short-time current
|
18 kA
|
Result of thermal test
|
Test passed
|
Proof of thermal characteristics (needle flame) effective duration
|
30 s
|
Relative insulation material temperature index (Elec., UL 746 B)
|
130 °C
|
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
|
130 °C
|
Static insulating material application in cold
|
-60 °C
|
Surface flammability NFPA 130 (ASTM E 162)
|
passed
|
Specific optical density of smoke NFPA 130 (ASTM E 662)
|
passed
|
Calorimetric heat release NFPA 130 (ASTM E 1354)
|
28 MJ/kg
|
Smoke gas toxicity NFPA 130 (SMP 800C)
|
passed
|
Fire protection for rail vehicles (DIN EN 45545-2) R22
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R23
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R24
|
HL 1 - HL 3
|
Fire protection for rail vehicles (DIN EN 45545-2) R26
|
HL 1 - HL 3
|
Dimensions
Width
|
31 mm
|
Length
|
100 mm
|
Height
|
107.3 mm
|
Height NS 35/15
|
118.5 mm
|
Height NS 32
|
116 mm
|
Connection data
Note
|
Screws with hexagonal socket
|
Connection method
|
Screw connection
|
Screw thread
|
M10
|
Stripping length
|
40 mm
|
Tightening torque, min
|
25 Nm
|
Tightening torque max
|
30 Nm
|
Connection in acc. with standard
|
IEC 60947-7-1
|
Note
|
Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
|
Conductor cross section solid min.
|
35 mm²
|
Conductor cross section solid max.
|
150 mm²
|
Conductor cross section AWG min.
|
2
|
Conductor cross section AWG max.
|
300 kcmil
|
Conductor cross section flexible min.
|
50 mm²
|
Conductor cross section flexible max.
|
150 mm²
|
Min. AWG conductor cross section, flexible
|
1/0
|
Max. AWG conductor cross section, flexible
|
300 kcmil
|
Conductor cross section flexible, with ferrule without plastic sleeve min.
|
50 mm²
|
Conductor cross section flexible, with ferrule without plastic sleeve max.
|
150 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve min.
|
50 mm²
|
Conductor cross section flexible, with ferrule with plastic sleeve max.
|
150 mm²
|
Cross section with insertion bridge, solid max.
|
150 mm²
|
Cross section with insertion bridge, stranded max.
|
120 mm²
|
2 conductors with same cross section, solid min.
|
25 mm²
|
2 conductors with same cross section, solid max.
|
50 mm²
|
2 conductors with same cross section, stranded min.
|
35 mm²
|
2 conductors with same cross section, stranded max.
|
50 mm²
|
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
|
25 mm²
|
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
|
50 mm²
|
Internal cylindrical gage
|
B14
|
Ambient conditions
Operating temperature
|
-60 °C ... 105 °C (max. short-term operating temperature 125°C)
|
Ambient temperature (storage/transport)
|
-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
|
Permissible humidity (storage/transport)
|
30 % ... 70 %
|
Ambient temperature (assembly)
|
-5 °C ... 70 °C
|
Ambient temperature (actuation)
|
-5 °C ... 70 °C
|
Standards and Regulations
Connection in acc. with standard
|
CSA
|
|
IEC 60947-7-1
|
Flammability rating according to UL 94
|
V0
|
Environmental Product Compliance
China RoHS
|
Environmentally friendly use period: unlimited = EFUP-e
|
|
No hazardous substances above threshold values
|
ECLASS
ECLASS 10.0.1 |
27141120
|
ECLASS 11.0 |
27141120
|
ECLASS 4.0 |
27141100
|
ECLASS 4.1 |
27141100
|
ECLASS 5.0 |
27141100
|
ECLASS 5.1 |
27141100
|
ECLASS 6.0 |
27141100
|
ECLASS 7.0 |
27141120
|
ECLASS 9.0 |
27141120
|
ETIM
ETIM 2.0 |
EC000897
|
ETIM 3.0 |
EC000897
|
ETIM 4.0 |
EC000897
|
ETIM 6.0 |
EC000897
|
ETIM 7.0 |
EC000897
|
UNSPSC
UNSPSC 6.01 |
30211811
|
UNSPSC 7.0901 |
39121410
|
UNSPSC 11 |
39121410
|
UNSPSC 12.01 |
39121410
|
UNSPSC 13.2 |
39121410
|
UNSPSC 18.0 |
39121410
|
UNSPSC 19.0 |
39121410
|
UNSPSC 20.0 |
39121410
|
UNSPSC 21.0 |
39121410
|
|
File description
|
File type
|
Download link
|
|
|
|
|
|
|
|
|