Elit logo e-Elit - leading
electronic and automation component
online distributor
Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Braided Sleeve AGROflex, NW36 ø34..60mm, ratio 1:2, polyester PET 6, -50..150°C, HF, highly flexible, 100m/pck, Agro, black
Braided Sleeve AGROflex, NW36 ø34..60mm, ratio 1:2, polyester PET 6, -50..150°C, HF, highly flexible, 100m/pck, Agro, black



Extension Module PSR-SPP- 24UC/URM4/5X1/2X2/B, 1pcs/pck, Phoenix
Image is illustrative
Extension Module PSR-SPP- 24UC/URM4/5X1/2X2/B, 1pcs/pck, Phoenix
Code: 2981046
Cena
235,10 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.0214 kg/pc
Volume:
0.0004 m3/pc
Quantity:
Plus sign Minus sign
 

 

Extension Module PSR-SPP- 24UC/URM4/5X1/2X2/B, 1pcs/pck, Phoenix

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width 22.5 mm
Height 112 mm
Depth 114.5 mm

Ambient conditions

Ambient temperature (operation) -20 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 70 °C
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Maximum altitude max. 2000 m (Above sea level)

Input data

Rated control circuit supply voltage US 24 V AC/DC -15 % / +10 %
Rated control supply current IS typ. 81 mA AC
typ. 71 mA DC
Power consumption at US typ. 1.94 W (AC)
typ. 1.7 W (DC)
Inrush current 175 mA (Δt = 5 ms at Us)
Typ. starting time with Us < 20 ms (when controlled via A1)
Typical release time < 20 ms (when controlled via A1)
Recovery time < 1 s
Operating voltage display 1 x green LED
Protective circuit Surge protection Varistor
Maximum switching frequency 1 Hz
Filter time 2 ms (at A1 in the event of voltage dips at Us)

Output data

Contact type 5 enabling current paths
1 confirmation current path
1 signaling current path
Contact material AgSnO2
Maximum switching voltage 250 V AC/DC (Observe the load curve)
Minimum switching voltage 5 V AC/DC
Limiting continuous current 6 A (N/O contact, pay attention to the derating)
6 A (N/C contact)
Maximum inrush current 20 A (Δt  100 ms)
Inrush current, minimum 10 mA
Sq. Total current 72 A2 (observe derating)
Interrupting rating (ohmic load) max. 144 W (24 V DC, τ = 0 ms)
288 W (48 V DC, τ = 0 ms)
110 W (110 V DC, τ = 0 ms)
88 W (220 V DC, τ = 0 ms)
1500 VA (250 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load) 42 W (24 V DC, τ = 40 ms)
42 W (48 V DC, τ = 40 ms)
42 W (110 V DC, τ = 40 ms)
42 W (220 V DC, τ = 40 ms)
Switching capacity min. 50 mW
Mechanical service life 10x 106 cycles
Switching capacity (360/h cycles) 4 A (24 V DC)
4 A (230 V AC)
Output fuse 10 A gL/gG (N/O contact)
6 A gL/gG (N/C contact)

General

Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Nominal operating mode 100% operating factor
Net weight 20.4 g
Mounting position vertical or horizontal
Mounting type DIN rail mounting
Assembly instructions See derating curve
Degree of protection IP20
Min. degree of protection of inst. location IP54
Housing material Polyamide
Housing color yellow

Connection data

Connection method Push-in connection
pluggable Yes
Conductor cross section solid 0.2 mm² ... 1.5 mm²
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross-section AWG 24 ... 16
Conductor cross-section flexible with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section flexible with ferrule and plastic sleeve 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Stripping length 8 mm

Safety-related characteristic data

Stop category in accordance with IEC 60204 0
Designation IEC 61508 - High demand
Safety Integrity Level (SIL) 3 (In conjunction with suitable evaluating device)
Designation IEC 61508 - Low demand
Safety Integrity Level (SIL) 3 (In conjunction with suitable evaluating device)
Designation EN ISO 13849
Performance level (PL) e (In conjunction with suitable evaluating device)
Category 4 (In conjunction with suitable evaluating device)
Designation EN 62061
Safety Integrity Level (SIL) 3
Safety Integrity Level Claim Limit (SIL CL) In conjunction with suitable evaluating device

Standards and Regulations

Designation Air clearances and creepage distances between the power circuits
Standards/regulations DIN EN 50178/VDE 0160
Rated insulation voltage 250 V AC
Rated surge voltage/insulation Basic insulation 4 kV:
between all current paths and housing
Safe isolation, reinforced insulation 6 kV:
between A1/A2, 11/12, 23/24, 71/72 and 33/34, 43/44, 53/54, 63/64
Degree of pollution 2
Overvoltage category III
Shock 15g
Vibration (operation) 10 Hz ... 150 Hz, 2g
Conformance CE-compliant

Environmental Product Compliance

China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

ECLASS

ECLASS 10.0.1 27371819
ECLASS 11.0 27371819
ECLASS 4.0 40020600
ECLASS 4.1 40020600
ECLASS 5.0 27371900
ECLASS 5.1 27371900
ECLASS 6.0 27371800
ECLASS 7.0 27371819
ECLASS 9.0 27371819

ETIM

ETIM 2.0 EC001449
ETIM 3.0 EC001449
ETIM 4.0 EC001449
ETIM 6.0 EC001449
ETIM 7.0 EC001449

UNSPSC

UNSPSC 6.01 30211901
UNSPSC 7.0901 39121501
UNSPSC 11 39121501
UNSPSC 12.01 39121501
UNSPSC 13.2 39121501
UNSPSC 18.0 39122205
UNSPSC 19.0 39122205
UNSPSC 20.0 39122205
UNSPSC 21.0 39122205
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 
X
 
X