Elit logo e-Elit - leading
electronic and automation component
online distributor
Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Hole Saw Arbor, HEX Shank 8mm
Hole Saw Arbor, HEX Shank 8mm



Repeater Power Supply MACX MCR-SL-RPSSI-2I-SP, Phoenix
Image is illustrative
Repeater Power Supply MACX MCR-SL-RPSSI-2I-SP, Phoenix
Code: 2924838
Cena
528,70 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.1607 kg/pc
Volume:
0.0002 m3/pc
Quantity:
Plus sign Minus sign
 

 

Repeater Power Supply MACX MCR-SL-RPSSI-2I-SP, Phoenix

Note

Utilization restriction EMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width 12.5 mm
Height 116 mm
Depth 114.5 mm

Ambient conditions

Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
-20 °C ... 70 °C (any mounting position, module distance 5 mm, MTBF reduction factor 2.5, not assessed by UL)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Maximum altitude ≤ 2000 m
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Noise immunity EN 61000-6-2

Input data

Signal input Repeater power supply operation
Current input signal 4 mA ... 20 mA
Transmitter supply voltage > 21.5 V (20 mA)
> 21 V (23 mA)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)
Signal input Signal conditioner operation
Current input signal 0 mA ... 20 mA
4 mA ... 20 mA
Voltage drop < 3.9 V (in input isolating amplifier operation)
Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)

Output data

Signal output Repeater power supply operation
Current output signal 4 mA ... 20 mA (active)
0 mA ... 20 mA
Load/output load current output < 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple < 20 mVrms
Output behavior in the event of an error 0 mA (Cable break in the input)
≥ 23 mA (Cable short-circuit in the input)
Signal output Signal conditioner operation
Current output signal 0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
Load/output load current output < 450 Ω (20 mA)
< 380 Ω (23 mA)
Output ripple < 20 mVrms
Output behavior in the event of an error 0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)

Power supply

Designation Repeater power supply operation
Nominal supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption < 75 mA (24 V DC / 20 mA)
Power dissipation < 1.45 W (24 V DC / 20 mA)
Designation Signal conditioner operation
Nominal supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption < 46 mA (24 V DC / 20 mA)
Power dissipation < 1.2 W (24 V DC / 20 mA)

Connection data

Connection method Push-in connection
Stripping length 8 mm
Conductor cross section solid 0.2 mm² ... 1.5 mm²
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16

General

No. of channels 1
Maximum transmission error < 0.1 % (of final value)
Transmission error, typical < 0.05 % (of final value)
Maximum temperature coefficient < 0.01 %/K
Step response (10-90%) 1.3 ms (for jump 4 mA ... 20 mA, typical)
Status display Green LED (PWR supply voltage)
Electromagnetic compatibility Conformance with EMC directive
Interference emission EN 61000-6-4
Housing material PA 6.6-FR
Color gray
Designation Input/output/power supply
Rated insulation voltage 300 Vrms
Test voltage 2.5 kV AC (50 Hz, 1 min.)
Insulation Safe isolation in accordance with IEC/EN 61010-1
Overvoltage category II
Degree of pollution 2
Designation Output 1/output 2
Test voltage 1.5 kV AC (50 Hz, 1 min.)

Data communication (bypass)

HART function Yes
Protocols supported HART

EMC data

Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 3 %
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Typical deviation from the measuring range final value 3 %
Designation Conducted interferences
Standards/regulations EN 61000-4-6
Typical deviation from the measuring range final value 3 %

Standards and Regulations

Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
EN 61000-4-4
Designation Conducted interferences
Standards/regulations EN 61000-4-6

Conformance/approvals

Designation CE
Certificate CE-compliant
Additional text and EN 61326-1
Designation ATEX
Identification  II 3 G Ex nA IIC T4 Gc X
Designation UL, USA/Canada
Identification UL 508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Groups IIC, IIB, IIA T4
Designation UL, USA/Canada
Identification UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Designation Shipbuilding approval
Identification C, EMC2
Certificate DNV GL TAA000020C
Designation Safety Integrity Level (SIL, IEC 61508)
Identification 2
Temperature B
Humidity B
Vibration A
EMC A
Enclosure Required protection according to the Rules shall be provided upon installation on board

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

ECLASS

ECLASS 10.0.1 27210120
ECLASS 11.0 27210120
ECLASS 4.0 27210100
ECLASS 4.1 27210100
ECLASS 5.0 27210100
ECLASS 5.1 27210100
ECLASS 6.0 27210100
ECLASS 7.0 27210120
ECLASS 9.0 27210120

ETIM

ETIM 4.0 EC002653
ETIM 6.0 EC002653
ETIM 7.0 EC002653

UNSPSC

UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 39121008
UNSPSC 18.0 39121008
UNSPSC 19.0 39121008
UNSPSC 20.0 39121008
UNSPSC 21.0 39121008
 
 