Image is illustrative
|
Universal Temperature Converter KCD2-UT2-1, 1-ch., input TC/RTD/PM/V, current output 0/4..20mA, sink/source mode, conf. by PACTware, LFD, SBD, TS35, 24VDC PR, Pepperl+Fuchs Code:
253994
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.105 kg/pc
|
Volume:
0.0002 m3/pc
|
|
|
|
|
Universal Temperature Converter KCD2-UT2-1, 1-ch., input TC/RTD/PM/V, current output 0/4..20mA, sink/source mode, conf. by PACTware, LFD ?SBD, TS35, 24VDC PR, Pepperl+FuchsUniversal Temperature Converter KCD2-UT2-1
- 1-channel signal conditioner
- 24 V DC supply (Power Rail)
- Thermocouple, RTD, potentiometer or voltage input
- Current output 0/4 mA ... 20 mA
- Sink or source mode
- Configurable by PACTware
- Line fault (LFD) and sensor burnout detection
Datasheet excerpt: Technical data of KCD2-UT2-1
Product Description |
Current output 0/4 mA ... 20 mA |
General specifications |
Signal type | Analog input |
Supply |
Connection | terminals 9+, 10- or power feed module/Power Rail |
Rated voltage | 19 ... 30 V DC |
Ripple | within the supply tolerance |
Power dissipation/power consumption | ≤ 0.98 W / 0.98 W |
Interface |
Programming interface | programming socket |
Input |
Connection side | field side |
Connection | terminals 1, 2, 3, 4 |
RTD | type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760) |
| Measuring current | approx. 200 µA with RTD |
| Types of measuring | 2-, 3-, 4-wire connection |
| Lead resistance | max. 50 Ω per line |
| Measurement loop monitoring | sensor breakage, sensor short-circuit |
Thermocouples | type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001) |
| Cold junction compensation | external and internal |
| Measurement loop monitoring | sensor breakage |
Potentiometer | 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection) |
Voltage | selectable within the range -100 ... 100 mV |
Input resistance | ≥ 1 MΩ (-100 ... 100 mV) |
Output |
Connection side | control side |
Connection | terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+) |
Output | Analog current output |
| Current range | 0 ... 20 mA or 4 ... 20 mA |
| Fault signal | downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43) |
| Source | load 0 ... 550 Ω open-circuit voltage ≤ 18 V |
| Sink | Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V, series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 5)/0.0215 Ω. |
Transfer characteristics |
Reaction time | worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s |
Indicators/settings |
Display elements | LEDs |
Configuration | via PACTware |
Labeling | space for labeling at the front |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity |
Electromagnetic compatibility | NE 21:2011 |
Degree of protection | IEC 60529:2001 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications |
Degree of protection | IP20 |
Connection | screw terminals |
Mass | approx. 100 g |
Dimensions | 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2 |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
|
|
|
|