Heat Shrink Tubing H-2(Z), 19/9.5mm, thin-wall 0.8mm, crosslinked polyolefin -55..125°C/ +100°C, flame resistant, high flexibility, L1.22m/pc, blue
Heat Shrink Tubing H-2(Z), 19/9.5mm, thin-wall 0.8mm, crosslinked polyolefin -55..125°C/ +100°C, flame resistant, high flexibility, L1.22m/pc, blue



Hybrid Motor Starter ELR W3-24DC/500AC-2I, Phoenix
Image is illustrative
Hybrid Motor Starter ELR W3-24DC/500AC-2I, Phoenix
Code: 2297031
Cena
257,60 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.2968 kg/pc
Volume:
0.0003 m3/pc
Quantity:
Plus sign Minus sign
 

 

Hybrid Motor Starter ELR W3-24DC/500AC-2I, Phoenix

Dimensions

Width 22.5 mm
Height 107 mm
Depth 114 mm

Ambient conditions

Ambient temperature (operation) -25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Maximum altitude ≤ 2000 m
Degree of protection IP20

Device supply

Rated control circuit supply voltage US 24 V DC
Control supply voltage range 19.2 V DC ... 30 V DC
Rated control supply current IS 40 mA
Type of protection Surge protection
Reverse polarity protection

Input data

Input name Control input right/left
Rated actuating voltage UC 24 V DC
Triggering voltage range 19.2 V DC ... 30 V DC
Rated actuating current IC 5 mA
Switching threshold 9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level < 5 V DC (For EMERGENCY STOP)
Typical response time < 35 ms
Typical turn-off time < 40 ms

Output data load output

Output name AC output
Rated operating voltage Ue 500 V AC
Operating voltage range 42 V AC ... 550 V AC
Rated operating current Ie 2.4 A (AC-51)
2.4 A (AC-53a)
Mains frequency 50/60 Hz
Load current range 180 mA ... 2.4 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2 Class 10A
Cooling time 20 min. (for auto reset)
Leakage current 0 mA
Residual voltage < 0.3 V
Surge current 100 A (t = 10 ms)
Type of protection Surge protection

Output data reply output

Output name Acknowledge output
Note Confirmation: floating change-over contact, signal contact
Contact type 1 changeover contact
Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15)
2 A (24 V, DC13)

General

Motor starter type Reversing starter
Switching frequency ≤ 2 Hz (Load-dependent)
Mounting position Vertical (horizontal DIN rail)
Mounting type DIN rail mounting
Assembly instructions Can be aligned with spacing = 20 mm
Operating mode 100% operating factor
Maximum power dissipation 3.3 W
Minimum power dissipation 1.1 W
Operating voltage display Green LED
Status display Yellow LED
Indication Red LED

Connection data

Connection name Control circuits
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.

Connection data 2

Connection name Load circuit
Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Torque 0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.

Insulation characteristics

Rated insulation voltage 500 V
Rated surge voltage 6 kV
Overvoltage category III
Degree of pollution 2
Designation Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit
Insulation Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
Designation Isolation characteristics between the control input and control supply voltage to auxiliary circuit
Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC

Standards and Regulations

Designation Standards/regulations
Standards/regulations DIN EN 50178
EN 60947
IEC 61508
ISO 13849

Conformance/approvals

Designation ATEX
Identification  II (2) G [Ex e] [Ex d] [Ex px]
 II (2) D [Ex t] [Ex p]
Certificate PTB 07 ATEX 3145
Designation UL approval
Certificate NLDX.E228652
Designation Safety Integrity Level (SIL, IEC 61508)
Identification ≤ 3
Additional text Safe shutdown
Designation Safety Integrity Level (SIL, IEC 61508)
Identification 2
Additional text Motor protection
Designation Performance Level (ISO 13849)
Identification ≤ e
Additional text Safe shutdown
Designation Category (ISO 13849)
Identification ≤ 3
Additional text Safe shutdown

UL data

SCCR 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA 2.4 A (500 V AC)
Group installation 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category code NLDX

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50 years
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

ECLASS

ECLASS 10.0.1 27370905
ECLASS 11.0 27370905
ECLASS 4.0 27021100
ECLASS 4.1 27021100
ECLASS 5.0 27024000
ECLASS 5.1 27024000
ECLASS 6.0 27024000
ECLASS 7.0 27024002
ECLASS 9.0 27370905

ETIM

ETIM 2.0 EC001037
ETIM 3.0 EC001037
ETIM 4.0 EC001037
ETIM 6.0 EC001037
ETIM 7.0 EC001037

UNSPSC

UNSPSC 6.01 30211915
UNSPSC 7.0901 39121514
UNSPSC 11 39121514
UNSPSC 12.01 39121514
UNSPSC 13.2 25173902
UNSPSC 18.0 25173902
UNSPSC 19.0 25173902
UNSPSC 20.0 25173902
UNSPSC 21.0 25173902
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 
X
 
X