|
|
Image is illustrative
|
Digital Input Module Micro850, 8-ch., 120VAC, 450mA inrush, Allen-Bradley Code:
2085-IA8
Cena (indicative)
Manufacturer
:
Availability:
ask for dd
|
Weight:
0.177 kg/pc
|
Volume:
0.001 m3/pc
|
|
|
|
|
Digital Input Module Micro850, 8-ch., 120VAC, 450mA inrush, Allen-Bradley
DESCRIPTIONS
-
Digital Input Module, Number Of Channels: 8, Input: Voltage: 120 VAC, Operating Voltage Range: 74 - 120 VAC, Off-State Voltage: 20 VAC (Maximum), Off-State Current: 2.5 MA (Maximum), On-State Current: 5 MA At 74 VAC (Minimum), On-State Current: 12.5 MA At 120 VAC (Maximum), Current Rating: Inrush: 450 MA, Isolation: 150 V (Continuous), Reinforced Insulation Type, Channel To System Type Tested At 1950 VDC For 60 SEC, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire, Length: 3.54 IN, Width: 3.42 IN, Height: 1.1 IN, Temperature Rating: -4 To 149 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock: 25 G (Operating), 25 G/35 G DIN Rail Mounting/Panel Mounting (Non-Operating), Response Time: Input Filter Time (Off To On/On To Off): Less Than Or Equal To 20 MS, Power Dissipation: 2.36 W, Impedance: 22.2 KOHM, Bus Rating: 150 MA At 5 VDC, Indicator: 8 Yellow, Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Power/Shielded Ports, Standard/Approvals: C/US UL listed, CE marked, C-Tick certified, KC certified
SPECIFICATIONS
-
-
Item Name: Digital Input Module
-
Number Of Channels: 8
-
Input: Voltage: 120 VAC, Operating Voltage Range: 74 - 120 VAC, Off-State Voltage: 20 VAC (Maximum), Off-State Current: 2.5 MA (Maximum), On-State Current: 5 MA At 74 VAC (Minimum), On-State Current: 12.5 MA At 120 VAC (Maximum)
-
Current Rating: Inrush: 450 MA
-
Isolation: 150 V (Continuous), Reinforced Insulation Type, Channel To System Type Tested At 1950 VDC For 60 SEC
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire
-
Length: 3.54 IN
-
Width: 3.42 IN
-
Height: 1.1 IN
-
Temperature Rating: -4 To 149 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock: 25 G (Operating), 25 G/35 G DIN Rail Mounting/Panel Mounting (Non-Operating)
-
Response Time: Input Filter Time (Off To On/On To Off): Less Than Or Equal To 20 MS
-
Power Dissipation: 2.36 W
-
Indicator: 8 Yellow
-
Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Power/Shielded Ports
-
Impedance: 22.2 KOHM
-
Bus Rating: 150 MA At 5 VDC
FEATURES
-
- AC discrete modules to suit different applications
- Solid state output modules for applications which require more versitile outputs than relays
- High density discrete modules to reduce space consumption
- Standards: C/US UL listed, CE marked, C-Tick certified, KC certified
|
|
|
|