Image is illustrative
|
Digital DC Output Module FlexI/O, 16-ch., 24VDC, TS35, panel mount, Allen-Bradley Code:
1794-OB16D
Cena (indicative)
Manufacturer
:
Availability:
14 days
|
Weight:
0.116 kg/pc
|
Volume:
0.0004 m3/pc
|
|
|
|
|
Digital DC Output Module FlexI/O, 16-ch., 24VDC, TS35 ˄panel mount, Allen-Bradley
DESCRIPTIONS
-
Flex™ Digital DC Output Module, Number Of Channels: 16 (Isolated), Output: On-State Current: 2 MA Minimum Per Output, 0.5 A Per Output, 8 A Per Module Maximum, Output Current Rating: 8 A (16 Outputs At 0.5 A), Off-State Voltage: 31.2 VDC Maximum, Off-State Leakage: 0.5 MA Maximum, On-State Voltage Drop: 0.5 VDC At 0.5 A, Voltage Rating: 24 VDC/10 - 31.2 VDC, Isolation: Tested At 2121 VDC For 1 SEC Between User And System, No Isolation Between Individual Channels, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 1890 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 12 AWG Stranded Copper Wire, Mounting: DIN Rail, Panel, Length: 3.7 IN, Width: 2.1 IN, Height: 1.8 IN, Temperature Rating: 32 - 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 5 G At 10 - 500 HZ, Shock - Operating: 30 G, Non-Operating: 50 G, Power Dissipation: 4.8 W At 31.2 VDC, Output Type: Current Sourcing, Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal Ports, Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Power Ports, Indicator: 16 Yellow On/Off Status Indicators (Field Side), 16 Red Diagnostic Status Indicators (Each Channel, Field Side), 1 Red Module Fault Indicator (Field Side), Surge Current: 2 A For 50 MS, Bus Rating: Flexbus Current: 60 MA, Keyswitch Position: 2, Standard/Approvals: C/US UL listed, CSA certified, CE-EMC, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-LR, ROSTECHNADZOR, Application: For in-cabinets
SPECIFICATIONS
-
-
Item Name: Digital DC Output Module
-
Sub Brand: Flex™
-
Number Of Channels: 16 (Isolated)
-
Output: On-State Current: 2 MA Minimum Per Output, 0.5 A Per Output, 8 A Per Module Maximum, Output Current Rating: 8 A (16 Outputs At 0.5 A), Off-State Voltage: 31.2 VDC Maximum, Off-State Leakage: 0.5 MA Maximum, On-State Voltage Drop: 0.5 VDC At 0.5 A
-
Voltage Rating: 24 VDC/10 - 31.2 VDC
-
Isolation: Tested At 2121 VDC For 1 SEC Between User And System, No Isolation Between Individual Channels
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 Hz 50% Pulse 100% AM At 1890 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Connection Cables: 12 AWG Stranded Copper Wire
-
Mounting: DIN Rail, Panel
-
Length: 3.7 IN
-
Width: 2.1 IN
-
Height: 1.8 IN
-
Temperature Rating: 32 - 131 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 5 G At 10 - 500 HZ, Shock - Operating: 30 G, Non-Operating: 50 G
-
Power Dissipation: 4.8 W At 31.2 VDC
-
Output Type: Current Sourcing
-
Indicator: 16 Yellow On/Off Status Indicators (Field Side), 16 Red Diagnostic Status Indicators (Each Channel, Field Side), 1 Red Module Fault Indicator (Field Side)
-
Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal Ports, Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Power Ports
-
Surge Current: 2 A For 50 MS
-
Keyswitch Position: 2
-
Bus Rating: Flexbus Current: 60 MA
FEATURES
-
- Standards: C/US UL listed, CSA certified, CE-EMC, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-LR, ROSTECHNADZOR
- Applications: For in-cabinets
|
File description
|
File type
|
Download link
|
|
|
|
"
Spec Sheet
|
.pdf
|
Download link
|
|
|
|
|
|
|
|