Image is illustrative
|
Digital AC Input Module Flex™, 8-ch., input 12mA 120VAC 60Hz, EtherNet/IP/ ControlNet/ DeviceNet/ Profibus DP, panel mount, TS35, 85..132VAC, Allen-Bradley Code:
1794-IA8
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.204 kg/pc
|
Volume:
0.0015 m3/pc
|
|
|
|
|
Digital AC Input Module Flex™, 8-ch., input 12mA 120VAC 60Hz, EtherNet/IP/ ControlNet/ DeviceNet/ Profibus DP, panel mount ?TS35, 85..132VAC, Allen-Bradley
DESCRIPTIONS
-
Flex™ Digital AC Input Module, Number Of Channels: 8 (Non-Isolated), Input: On-State Voltage: 65 VAC (Minimum), 120 VAC Nominal, 132 VAC (Maximum), On-State Current: 7.1 MA (Minimum), Off-State Voltage: 43 VAC (Maximum), Off-State Current: 2.9 MA (Minimum), Nominal: 12 MA At 120 VAC, 60 HZ, Voltage Rating: 85 - 132 VAC At 47 - 63 HZ, Isolation: 2150 VDC (For 1 SEC Between User And System), Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 30 - 1000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 HZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 22 - 12 AWG Stranded Copper Wire, Communication: EtherNet/IP, ControlNet, DeviceNet And Profibus DP, Mounting: DIN Rail, Panel, Length: 3.7 IN, Width: 2.7 IN, Height: 3.7 IN, Temperature Rating: 32 - 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G, Shock: 50 G (Non-Operating), Power Dissipation: 4.5 W At 132 VAC, Keyswitch Position: 8, Indicator: 8 Yellow Status, Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal/Power Ports, Bus Rating: 30 MA At 5 VDC, Impedance: Input: 10.6 KOHM, Standard/Approvals: UL listed, CSA certified, CE-ATEX, CE-EMC, CE-LVD, C-TICK, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR, Application: For in-cabinets
SPECIFICATIONS
-
-
Item Name: Digital AC Input Module
-
Sub Brand: Flex™
-
Number Of Channels: 8 (Non-Isolated)
-
Input: On-State Voltage: 65 VAC (Minimum), 120 VAC Nominal, 132 VAC (Maximum), On-State Current: 7.1 MA (Minimum), Off-State Voltage: 43 VAC (Maximum), Off-State Current: 2.9 MA (Minimum), Nominal: 12 MA At 120 VAC, 60 HZ
-
Voltage Rating: 85 - 132 VAC At 47 - 63 HZ
-
Isolation: 2150 VDC (For 1 SEC Between User And System)
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 30 - 1000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 HZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
-
Connection Cables: 22 - 12 AWG Stranded Copper Wire
-
Communication: EtherNet/IP, ControlNet, DeviceNet And Profibus DP
-
Mounting: DIN Rail, Panel
-
Length: 3.7 IN
-
Width: 2.7 IN
-
Height: 3.7 IN
-
Temperature Rating: 32 - 131 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G, Shock: 50 G (Non-Operating)
-
Power Dissipation: 4.5 W At 132 VAC
-
Indicator: 8 Yellow Status
-
Surge Transient Immunity: Plus/Minus 1 KV Line-Line(DM) And Plus/Minus 2 KV Line-Earth(CM) On Signal/Power Ports
-
Impedance: Input: 10.6 KOHM
-
Keyswitch Position: 8
-
Bus Rating: 30 MA At 5 VDC
FEATURES
-
The FLEX I/O module plugs into the terminal base, connecting to the I/O bus and field devices. Since there is no direct wiring to the I/O module, modules can be removed and inserted under power, enabling to change modules without disturbing field wiring, other I/O modules, or system power. This eliminates costly downtime and the inefficiencies of restarting a system. - LED for each channel indicating status of: corresponding input device, output signal
- Standards: UL listed, CSA certified, CE-ATEX, CE-EMC, CE-LVD, C-TICK, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR
- Applications: For in-cabinets
|
|
|
|