Digital DC I/O Module Compact Logix, 32-ch., 24VDC, 300mA 5.1V drawn, TS35, panel mount, Allen-Bradley Code:
1769-OB32
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.433 kg/pc
|
Volume:
0.0015 m3/pc
|
|
|
|
|
Output Module CompactLogix, 32-point 24VDC solid-state source, Allen-Bradley
DESCRIPTIONS
CompactLogix™ Digital DC I/O Module, Number Of Channels: 32 (16 Points/Group), Output: Operating Voltage: 20.4 - 26.4 VDC, Off-State Leakage Current: 1 MA At 26.4 VDC (Maximum), On-State Current: 1 MA (Minimum), On-State Voltage Drop: 1 VDC At 1 A (Maximum), Voltage Rating: 24 VDC, Current Rating: Drawn: 300 MA At 5.1 V, Current Per Point: 0.5 A At 60 DEG C, 1 A At 30 DEG C, Current Per Module: 4 A At 60 DEG C, 8 A At 30 DEG C, Isolation: 1200 VAC For 1 SEC Or 1697 VDC For 1 SEC, Output Point To Bus, 75 VDC Working Voltage, Enclosure: Open Type, Display: Status LED, Connection Cables: 22 - 14 AWG Solid, 22 - 16 AWG Stranded, Mounting: DIN Rail, Panel, Length: 2.07 IN, Width: 3.43 IN, Height: 4.65 IN, Temperature Rating: 32 - 140 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G At 10 - 500 HZ (Operating), 2 G (Relay Operating), Shock - Panel Mount: 30 G (Operating), 7.5 G (Relay Operating), 40 G (Non-Operating), DIN Rail Mount: 20 G (Operating), 5 G (Relay Operating), 30 G (Non-Operating), Response Time: Delay (On): 0.1 MS, Delay (Off): 1 MS, Power Dissipation: 4.5 W, Output Type: Current Sourcing, Slot Width: 1-1/2, Surge Current: 2 A For 10 MS, Repeatable Every 2 SEC, Standard/Approvals: C/US UL listed, UL 508 listed, CSA C22.2, file number 142, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR
|
|
SPECIFICATIONS
- Item Name: Digital DC I/O Module
- Sub Brand: CompactLogix™
- Number Of Channels: 32 (16 Points/Group)
- Output: Operating Voltage: 20.4 - 26.4 VDC, Off-State Leakage Current: 1 MA At 26.4 VDC (Maximum), On-State Current: 1 MA (Minimum), On-State Voltage Drop: 1 VDC At 1 A (Maximum)
- Voltage Rating: 24 VDC
- Current Rating: Drawn: 300 MA At 5.1 V, Current Per Point: 0.5 A At 60 DEG C, 1 A At 30 DEG C, Current Per Module: 4 A At 60 DEG C, 8 A At 30 DEG C
- Isolation: 1200 VAC For 1 SEC Or 1697 VDC For 1 SEC, Output Point To Bus, 75 VDC Working Voltage
- Enclosure: Open Type
- Display: Status LED
- Connection Cables: 22 - 14 AWG Solid, 22 - 16 AWG Stranded
- Mounting: DIN Rail, Panel
- Length: 2.07 IN
- Width: 3.43 IN
- Height: 4.65 IN
- Temperature Rating: 32 - 140 DEG F
- Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G At 10 - 500 HZ (Operating), 2 G (Relay Operating), Shock - Panel Mount: 30 G (Operating), 7.5 G (Relay Operating), 40 G (Non-Operating), DIN Rail Mount: 20 G (Operating), 5 G (Relay Operating), 30 G (Non-Operating)
- Response Time: Delay (On): 0.1 MS, Delay (Off): 1 MS
- Power Dissipation: 4.5 W
- Output Type: Current Sourcing
- Surge Current: 2 A For 10 MS, Repeatable Every 2 SEC
- Slot Width: 1-1/2
FEATURES
Most output modules have built-in surge suppression to reduce the effects of high-voltage transients. Use an additional suppression device if an output is being used to control inductive devices, such as relays, motor starters, solenoids, or motors. Additional suppression is especially important if your inductive device is in series with or parallel to hard contacts, such as push buttons or selector switches. Add a suppression device directly across the coil of an inductive device to reduce the effects of voltage transients caused by interrupting the current to that device and to prolong the life of the switch contacts.
Logic circuits determine the output status
An output LED indicates the status of the output signal
Optical isolation separates module logic and bus circuits from field power
The output driver turns the corresponding output on or off
Standards: C/US UL listed, UL 508 listed, CSA C22.2, file number 142, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR
|
|
|
|