Hazloc Beacon, xenon 5J strobe, -4..131°F, PPS glass filled plastic/glass, ss304 mounting bracket, Vitongasket, ½-in. NPT conduit, 24VDC, IP66, NEMA4/4X/13, Allen-Bradley, blue
Hazloc Beacon, xenon 5J strobe, -4..131°F, PPS glass filled plastic/glass, ss304 mounting bracket, Vitongasket, ½-in. NPT conduit, 24VDC, IP66, NEMA4/4X/13, Allen-Bradley, blue



Digital AC I/O Module CompactLogix, 16-ch., 100/240VAC, 225mA 5.1V drawn, Allen-Bradley
Image is illustrative
Digital AC I/O Module CompactLogix, 16-ch., 100/240VAC, 225mA 5.1V drawn, Allen-Bradley
Code: 1769-OA16
Cena (indicative)
407,00 €  /pc
Manufacturer :
Availability:
ask for dd
Weight:
0.375 kg/pc
Volume:
0.0015 m3/pc
Quantity:
Plus sign Minus sign
 

 

Digital AC I/O Module CompactLogix, 16-ch., 100/240VAC, 225mA 5.1V drawn, Allen-Bradley

DESCRIPTIONS
CompactLogix™ Digital AC I/O Module, Number Of Channels: 16 (8 Points/Group), Output: Operating Voltage: 85 - 265 VAC, 47 - 63 HZ, Off-State Leakage Current: 2 MA At 132 VAC (Maximum), 2.5 MA At 265 VAC (Maximum), On-State Current: 10 MA (Maximum), On-State Voltage Drop: 1.5 V Peak At 2 A (Maximum), Voltage Rating: 100/240 VAC, Current Rating: Drawn: 225 MA At 5.1 V, Current Per Point: 0.25 A At 60 DEG C (Maximum), 0.5 A At 30 DEG C (Maximum), Current Per Module: 2 A At 60 DEG C (Maximum), 4 A At 30 DEG C (Maximum), Isolation: 1836 VAC For 1 SEC Or 2596 VDC For 1 SEC, Output Point To Bus, 265 VAC Working Voltage, 150 VAC Working Voltage, Enclosure: Open Type, Display: Status LED, Connection Cables: 22 - 14 AWG Solid, 22 - 16 AWG Stranded, Mounting: DIN Rail, Panel, Length: 1.38 IN, Width: 3.43 IN, Height: 4.65 IN, Temperature Rating: 32 - 140 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G At 10 - 500 HZ (Operating), 2 G (Relay Operating), Shock - Panel Mount: 30 G (Operating), 7.5 G (Relay Operating), 40 G (Non-Operating), DIN Rail Mount: 20 G (Operating), 5 G (Relay Operating), 30 G (Non-Operating), Response Time: Delay (On): 1/2 Cycle, Delay (Off): 1/2 Cycle, Power Dissipation: 4.9 W, Slot Width: 1, Surge Current: 5 A For 25 MS, Repeatable Every 2 SEC, Standard/Approvals: C/US UL listed, UL 508 listed, CSA C22.2, file number 142, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR
SPECIFICATIONS
  • Item Name: Digital AC I/O Module

  • Sub Brand: CompactLogix™

  • Number Of Channels: 16 (8 Points/Group)

  • Output: Operating Voltage: 85 - 265 VAC, 47 - 63 HZ, Off-State Leakage Current: 2 MA At 132 VAC (Maximum), 2.5 MA At 265 VAC (Maximum), On-State Current: 10 MA (Maximum), On-State Voltage Drop: 1.5 V Peak At 2 A (Maximum)

  • Voltage Rating: 100/240 VAC

  • Current Rating: Drawn: 225 MA At 5.1 V, Current Per Point: 0.25 A At 60 DEG C (Maximum), 0.5 A At 30 DEG C (Maximum), Current Per Module: 2 A At 60 DEG C (Maximum), 4 A At 30 DEG C (Maximum)

  • Isolation: 1836 VAC For 1 SEC Or 2596 VDC For 1 SEC, Output Point To Bus, 265 VAC Working Voltage, 150 VAC Working Voltage

  • Enclosure: Open Type

  • Display: Status LED

  • Connection Cables: 22 - 14 AWG Solid, 22 - 16 AWG Stranded

  • Mounting: DIN Rail, Panel

  • Length: 1.38 IN

  • Width: 3.43 IN

  • Height: 4.65 IN

  • Temperature Rating: 32 - 140 DEG F

  • Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 5 G At 10 - 500 HZ (Operating), 2 G (Relay Operating), Shock - Panel Mount: 30 G (Operating), 7.5 G (Relay Operating), 40 G (Non-Operating), DIN Rail Mount: 20 G (Operating), 5 G (Relay Operating), 30 G (Non-Operating)

  • Response Time: Delay (On): 1/2 Cycle, Delay (Off): 1/2 Cycle

  • Power Dissipation: 4.9 W

  • Surge Current: 5 A For 25 MS, Repeatable Every 2 SEC

  • Slot Width: 1

FEATURES

Most output modules have built-in surge suppression to reduce the effects of high-voltage transients. Use an additional suppression device if an output is being used to control inductive devices, such as relays, motor starters, solenoids, or motors. Additional suppression is especially important if your inductive device is in series with or parallel to hard contacts, such as push buttons or selector switches. Add a suppression device directly across the coil of an inductive device to reduce the effects of voltage transients caused by interrupting the current to that device and to prolong the life of the switch contacts.

  • Logic circuits determine the output status
  • An output LED indicates the status of the output signal
  • Optical isolation separates module logic and bus circuits from field power
  • The output driver turns the corresponding output on or off
  • Standards: C/US UL listed, UL 508 listed, CSA C22.2, file number 142, C-TICK certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, MARINE-LR certified, ROSTECHNADZOR
 
 