Image is illustrative
|
Digital, Analog I/O Controller MicroLogix, 32-ch., 20kB, Allen-Bradley Code:
1766-L32BWAA
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
1.3 kg/pc
|
Volume:
0.0054 m3/pc
|
|
|
|
|
SPLC MicroLogix 1400, 12 DI fast 24VDC, 8 DI normal 24VDC, 12 RO, 4 AI (12 bits), 2 AO (12 bits), 110/240VAC, Rockwell Automation
DESCRIPTIONS
MicroLogix™ Digital And Analog I/O Controller, Memory: 20 KB Battery-Backed RAM, 10 KB User Program, 10 KB User Data, Interface: Ethernet Port, Isolated RS-232/RS-485 And Non-Isolated RS-232C Serial Ports, DF1, DH-485, ASCII, Communication: Modbus RTU, DNP3, EtherNet/IP Messaging, DNP3 over IP, Modbus TCP/IP, Number Of Channels: 32 (20 Input, 12 Output), Mounting: DIN Rail, Panel, Input: On-State Voltage Range: 10 - 24 VDC, Off-State Voltage Range: 0 - 5 VDC, Operating Frequency: 0 - 1 KHZ, On-State Current: 5.3 MA At 24 VDC, Off-State Leakage Current: 1.5 MA, Analog Input - Voltage Input Range: 0 - 10 VDC - 1 LSB, Voltage Input Overvoltage Protection: 10.5 VDC, Output: Analog - Voltage Output Range: 0 - 10 VDC - 1 LSB, Load Range Voltage Output: 1 KOHM, Response Time: Turn On/Off Time: 10 MS, Analog Output Setting Time: 3 MS, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 1.4 - 2 GHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2 - 2.7 GHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Display: LCD, Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire, Analog Output - 98 FT Shielded Cable, Length: 7.087 IN, Width: 3.43 IN, Height: 3-1/2 IN, Temperature Rating: -4 To 140 DEG F, Environmental Conditions: Operating Humidity: 5 - 95% (Non-Condensing), Vibration: 3 G, Shock - Operating Shock: 30 G, Non-Operating Shock: 50 G (Panel), 40 G (DIN Mount), Current Rating: Inrush: 25 A For 8 MS At 120 VAC, 40 A For 4 MS At 240 VAC, Current Per Channel And Group Common: 2.5 A Per Channel, 8A Max Channel 8 - 11 Common, Current Per Controller At 150 V: 28 A Or Total Of Per-Point Loads, Whichever Is Less, Current Per Controller At 240 V: 20 A Or Total Of Per-Point Loads, Whichever Is Less, Power Consumption: 120 VA, Maximum Controlled Load: 1440 VA, Standard/Approvals: C/US UL listed, UL file number E10314, CE, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-GL, marine-KRS, marine-LR, ROSTECHNADZOR, Application: For material handling, packaging applications, general industrial machinery, printing, food and beverage, pharmaceutical, water wastewater/scada, clutch/brake control, position control - pick-and-place/conveyor
|
|
SPECIFICATIONS
- Item Name: Digital And Analog I/O Controller
- Sub Brand: MicroLogix™
- Memory: 20 KB Battery-Backed RAM, 10 KB User Program, 10 KB User Data
- Interface: Ethernet Port, Isolated RS-232/RS-485 And Non-Isolated RS-232C Serial Ports, DF1, DH-485, ASCII
- Communication: Modbus RTU, DNP3, EtherNet/IP Messaging, DNP3 over IP, Modbus TCP/IP
- Number Of Channels: 32 (20 Input, 12 Output)
- Mounting: DIN Rail, Panel
- Input: On-State Voltage Range: 10 - 24 VDC, Off-State Voltage Range: 0 - 5 VDC, Operating Frequency: 0 - 1 KHZ, On-State Current: 5.3 MA At 24 VDC, Off-State Leakage Current: 1.5 MA, Analog Input - Voltage Input Range: 0 - 10 VDC - 1 LSB, Voltage Input Overvoltage Protection: 10.5 VDC
- Output: Analog - Voltage Output Range: 0 - 10 VDC - 1 LSB, Load Range Voltage Output: 1 KOHM
- Response Time: Turn On/Off Time: 10 MS, Analog Output Setting Time: 3 MS
- Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 1.4 - 2 GHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2 - 2.7 GHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ
- Display: LCD
- Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire, Analog Output - 98 FT Shielded Cable
- Length: 7.087 IN
- Width: 3.43 IN
- Height: 3-1/2 IN
- Temperature Rating: -4 To 140 DEG F
- Environmental Conditions: Operating Humidity: 5 - 95% (Non-Condensing), Vibration: 3 G, Shock - Operating Shock: 30 G, Non-Operating Shock: 50 G (Panel), 40 G (DIN Mount)
- Current Rating: Inrush: 25 A For 8 MS At 120 VAC, 40 A For 4 MS At 240 VAC, Current Per Channel And Group Common: 2.5 A Per Channel, 8A Max Channel 8 - 11 Common, Current Per Controller At 150 V: 28 A Or Total Of Per-Point Loads, Whichever Is Less, Current Per Controller At 240 V: 20 A Or Total Of Per-Point Loads, Whichever Is Less
- Power Consumption: 120 VA, Maximum Controlled Load: 1440 VA
FEATURES
Combining the features such as EtherNet/IP, online editing and a built-in LCD, plus adding enhanced features, such as increased I/O, faster High Speed Counter/PTO and communication capabilities. Use the embedded LCD to set the Ethernet network configuration, display floating point values on user-configurable display, set OEM logos, change file addresses, and increase the LCD data wiring capability to support a whole file.
Built-in RTC, Online Editing, 6 HSC, Up to 7 Expansion I/O
Ethernet port provides web server and e-mail capability
Built-in LCD with backlight allows you to view controller and I/O status, and provides a simple interface for messages, bit/integer monitoring and manipulation
Standards: C/US UL listed, UL file number E10314, CE, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-GL, marine-KRS, marine-LR, ROSTECHNADZOR