Image is illustrative
|
Digital Combination Module Module MicroLogix, 14-ch., input 8x 24VDC sink/source, output 6x relay contact 5..265VAC, TS35, panel mount, Allen-Bradley Code:
1762-IQ8OW6
Cena (indicative)
Manufacturer
:
Availability:
ask for dd
|
Weight:
0.268 kg/pc
|
Volume:
0.0009 m3/pc
|
|
|
|
|
Digital Combination Module Module MicroLogix, 14-ch., input 8x 24VDC sink/source, output 6x relay contact 5..265VAC, TS35?panel mount, Allen-Bradley
DESCRIPTIONS
-
MicroLogix™ Digital Combination Module, Type: Discrete, Number Of Channels: 14 (8 Input, 6 Output), Input: On-State Voltage: 10 VDC (Minimum), Off-State Voltage: 5 VDC (Maximum), On-State Current: 2 MA (Minimum), Off-State Current: 1.5 MA (Maximum), Output: Output Voltage: 5 - 265 VAC, 5- 125 VDC, Off Leakage Current: 0 MA, On-State Current (Minimum): 10 MA At 5 VDC, Continuous Current Per Module: 8 A, Total Controlled Load: 1440 VA/Module Maximum, Voltage Rating: 10 - 30 VDC At 30 DEG C, 10 - 26.4 VDC At 65 DEG C, Current Rating: Inrush: 250 MA, Enclosure: IP20, Rfi Suppression: Radiated: 10 V/M, 80 - 1000 MHZ, 80% Amplitude Modulation, 900 MHZ Keyed Carrier, Conducted: 10 V, 0.15 - 80 MHZ, Mounting: DIN Rail, Panel, Length: 1.59 IN, Width: 3.425 IN, Height: 3.543 IN, Temperature Rating: -4 To 149 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration Operating: 10 - 500 HZ, 5 G, 0.030 IN Max Peak-To-Peak, 2 HR Per Axis, Relay Operation: 1.5 G, Shock - Operating: 30 G Panel Mounted, 3 Pulses Per Axis, Relay Operation: 7 G, Non-Operating: 50 G Panel Mounted, 3 Pulses Per Axis (40 G DIN Rail Mounted), Response Time: Input Signal Delay - On Delay: 8 MS, Off Delay: 8 MS, Output Signal Delay - On Delay: 10 MS, Off Delay: 10 MS, Power Dissipation: Heat Dissipation: 5 W At 30 VDC, 4.4 W At 26.4 VDC, Output Type: Current Sinking/Source, Impedance: Nominal: 3 KOHM, Surge Transient Immunity: 2 KV Common Mode, 1 KV Differential Mode, Bus Rating: Bus Current Draw: 110 MA At 5 VDC, 80 MA At 24 VDC, Indicator: LED, Standard/Approvals: C/US UL listed, UL 508, UL 1604, CSA C22.2, file number 213, CE marked, class I, division 2, hazardous location, groups A, B, C, D, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-LR, ROSTECHNADZOR
SPECIFICATIONS
-
-
Item Name: Digital Combination Module
-
Type: Discrete
-
Sub Brand: MicroLogix™
-
Number Of Channels: 14 (8 Input, 6 Output)
-
Input: On-State Voltage: 10 VDC (Minimum), Off-State Voltage: 5 VDC (Maximum), On-State Current: 2 MA (Minimum), Off-State Current: 1.5 MA (Maximum)
-
Output: Output Voltage: 5 - 265 VAC, 5- 125 VDC, Off Leakage Current: 0 MA, On-State Current (Minimum): 10 MA At 5 VDC, Continuous Current Per Module: 8 A, Total Controlled Load: 1440 VA/Module Maximum
-
Voltage Rating: 10 - 30 VDC At 30 DEG C, 10 - 26.4 VDC At 65 DEG C
-
Current Rating: Inrush: 250 MA
-
Enclosure: IP20
-
Rfi Suppression: Radiated: 10 V/M, 80 - 1000 MHZ, 80% Amplitude Modulation, 900 MHZ Keyed Carrier, Conducted: 10 V, 0.15 - 80 MHZ
-
Mounting: DIN Rail, Panel
-
Length: 1.59 IN
-
Width: 3.425 IN
-
Height: 3.543 IN
-
Temperature Rating: -4 To 149 DEG F
-
Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration Operating: 10 - 500 HZ, 5 G, 0.030 IN Max Peak-To-Peak, 2 HR Per Axis, Relay Operation: 1.5 G, Shock - Operating: 30 G Panel Mounted, 3 Pulses Per Axis, Relay Operation: 7 G, Non-Operating: 50 G Panel Mounted, 3 Pulses Per Axis (40 G DIN Rail Mounted)
-
Response Time: Input Signal Delay - On Delay: 8 MS, Off Delay: 8 MS, Output Signal Delay - On Delay: 10 MS, Off Delay: 10 MS
-
Power Dissipation: Heat Dissipation: 5 W At 30 VDC, 4.4 W At 26.4 VDC
-
Output Type: Current Sinking/Source
-
Indicator: LED
-
Surge Transient Immunity: 2 KV Common Mode, 1 KV Differential Mode
-
Impedance: Nominal: 3 KOHM
-
Bus Rating: Bus Current Draw: 110 MA At 5 VDC, 80 MA At 24 VDC
FEATURES
-
The 1762 MicroLogix expansion I/O modules are compatible with MicroLogix 1100, MicroLogix 1200, and MicroLogix 1400 controllers. Install the expansion I/O modules to the right of the controller, either on a panel with two mounting screws or on a DIN rail. Use digital I/O modules in many combinations, up to the maximum supported by the controller. The current loading capacity of the controller’s built-in power supply may limit the actual number of I/O modules that can be connected to the controller. - Integrated high-performance I/O bus
- Software keying to prevent incorrect positioning within the system
- Finger-safe terminal blocks for I/O wiring
- Label to record I/O terminal designations
- Network support includes EtherNet/IP, DeviceNet, and DH-485 (local only)
- Standards: C/US UL listed, UL 508, UL 1604, CSA C22.2, file number 213, CE marked, class I, division 2, hazardous location, groups A, B, C, D, C-tick, GOST_R, KCC certified, marine-ABS, marine-BVS, marine-DNV, marine-GL, marine-LR, ROSTECHNADZOR
|
|
|
|