Elit logo e-Elit - leading
electronic and automation component
online distributor
Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Multi-Socket Plug, T-shaped 2x 2P+E Schuko 16A 230V, 1x  2USB Type A and 15W Type C, Legrand, white-black
Multi-Socket Plug, T-shaped 2x 2P+E Schuko 16A 230V, 1x 2USB Type A and 15W Type C, Legrand, white-black



Digital AC Output Module ControlLogix, 16-ch., 120/240VAC, 400mA 5.1V drawn, Allen-Bradley
Image is illustrative
Digital AC Output Module ControlLogix, 16-ch., 120/240VAC, 400mA 5.1V drawn, Allen-Bradley
Code: 1756-OA16
Cena (indicative)
489,60 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.383 kg/pc
Volume:
0.0023 m3/pc
Quantity:
Plus sign Minus sign
 

 

Digital AC Output Module ControlLogix, 16-ch., 120/240VAC, 400mA 5.1V drawn, Allen-Bradley

DESCRIPTIONS
ControlLogix® Digital AC Output Module, Number Of Channels: 16 (Mechanically Fused/Group), Output: Operating Voltage: 74 - 265 VAC, On-State Voltage Drop: 1.5 V At 0.5 A, 5.7 V At Load Current Less Than 50 MA, Voltage Rating: 120/240 VAC, Commutating Voltage: 4 V/MICSEC For Loads Greater Than 50 MA, 0.2 V/MICSEC For Loads Less Than 50 MA, Current Rating: Drawn: 400 MA At 5.1 V, 2 MA At 24 V, Off-State Leakage Current: 3 MA Per Point, Current Per Point: 0.5 A At 60 DEG C, Current Per Group: 2 A At 60 DEG C, Current Per Module: 4 A At 60 DEG C, Load Current: 10 MA Per Point, Isolation: 250 V (Continuous), Basic Insulation Type, Outputs-To-Backplane, And Output Group-To-Group, No Isolation Between Individual Group Outputs, 1350 VAC For 2 SEC Routine Test, Power Rating: Backplane: 0.66 W, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Display: Output, Module Health And Communication Status, Interface: Removable Terminal Block, Mounting: Chassis, Width: 1-23/64 IN, Height: 5-11/16 IN, Temperature Rating: 32 - 140 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock: 30 G(Operating), 50 G (Non-Operating), Response Time: Delay (Off To On): 9.3 MS At 60 HZ, 11 MS At 50 HZ, Delay (On To Off): 9.3 MS At 60 HZ, 11 MS At 50 HZ, Power Dissipation: 6.5 W At 60 DEG C, Surge Current: 5 A For 43 MS/Point, Repeatable Every 2 SEC At 60 DEG C/Point, 15 A For 43 MS/Point, Repeatable Every 2 SEC At 60 DEG C/Group, Slot Width: 1, Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports, Standard/Approvals: C/US UL listed, CSA certified, CE-EMC, CE-LVD, C-TICK, FM-US_HAZ, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR
SPECIFICATIONS
  • Item Name: Digital AC Output Module

  • Sub Brand: ControlLogix®

  • Number Of Channels: 16 (Mechanically Fused/Group)

  • Output: Operating Voltage: 74 - 265 VAC, On-State Voltage Drop: 1.5 V At 0.5 A, 5.7 V At Load Current Less Than 50 MA

  • Voltage Rating: 120/240 VAC, Commutating Voltage: 4 V/MICSEC For Loads Greater Than 50 MA, 0.2 V/MICSEC For Loads Less Than 50 MA

  • Current Rating: Drawn: 400 MA At 5.1 V, 2 MA At 24 V, Off-State Leakage Current: 3 MA Per Point, Current Per Point: 0.5 A At 60 DEG C, Current Per Group: 2 A At 60 DEG C, Current Per Module: 4 A At 60 DEG C, Load Current: 10 MA Per Point

  • Isolation: 250 V (Continuous), Basic Insulation Type, Outputs-To-Backplane, And Output Group-To-Group, No Isolation Between Individual Group Outputs, 1350 VAC For 2 SEC Routine Test

  • Power Rating: Backplane: 0.66 W

  • Enclosure: Open Type

  • Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ

  • Display: Output, Module Health And Communication Status

  • Interface: Removable Terminal Block

  • Mounting: Chassis

  • Width: 1-23/64 IN

  • Height: 5-11/16 IN

  • Temperature Rating: 32 - 140 DEG F

  • Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Vibration: 2 G, Shock: 30 G(Operating), 50 G (Non-Operating)

  • Response Time: Delay (Off To On): 9.3 MS At 60 HZ, 11 MS At 50 HZ, Delay (On To Off): 9.3 MS At 60 HZ, 11 MS At 50 HZ

  • Power Dissipation: 6.5 W At 60 DEG C

  • Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports

  • Surge Current: 5 A For 43 MS/Point, Repeatable Every 2 SEC At 60 DEG C/Point, 15 A For 43 MS/Point, Repeatable Every 2 SEC At 60 DEG C/Group

  • Slot Width: 1

FEATURES
  • Variety of voltage interface capabilities
  • Isolated and nonisolated module types
  • Point-level output fault states
  • Direct-connect or rack-optimized communication
  • Field-side diagnostics on select modules
  • Standards: C/US UL listed, CSA certified, CE-EMC, CE-LVD, C-TICK, FM-US_HAZ, GOST_R, KCC certified, MARINE-ABS, MARINE-BVS, MARINE-DNV, MARINE-GL, MARINE-KRS, MARINE-LR, ROSTECHNADZOR
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 
X
 
X