Analog RTD, TC Module ControlLogix, 8-ch., 30VDC, drawn 150mA 24V, Allen-Bradley Code:
1756-IRT8I
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.363 kg/pc
|
Volume:
0.0024 m3/pc
|
|
|
|
|
Analog RTD?TC Module ControlLogix, 8-ch., 30VDC, drawn 150mA 24V, Allen-Bradley
DESCRIPTIONS
-
ControlLogix® Analog RTD And Thermocouple Module, Number Of Channels: 8 (Isolated), Input: Input: 1 - 500 OHM, 2 - 1000 OHM, 4 - 2000 OHM, 8 - 4000 OHM, -100 To 100 MV, Voltage Rating: Overvoltage Protection: Plus/Minus 30 VDC, Current Rating: Drawn: 200 MA At 5.1 V, 150 MA At 24 V, RTD Excitation Current: 600 MICRO-A, Isolation: 250 V (Continuous), Reinforced Insulation Type, Inputs To Backplane, 250 V (Continuous), Basic Insulation Type, Input To Input, Type Tested At 2300 VAC For 60 SEC, Inputs To Backplane, Type Tested At 1500 VAC For 60 SEC, Input To Input, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ On Shielded Signal Ports, Connection Cables: 22 - 14 AWG Solid/Stranded Shielded Copper Wire, Temperature Rating: 32 - 140 DEG F, Environmental Conditions: 5 - 95% Non-Condensing Relative Humidity, Vibration: 2 G At 10 - 500 HZ, Shock - Operating: 30 G, Non-Operating: 50 G, Accuracy: Calibrated Accuracy At 25 DEG C: 0.05 %, Local CJC Sensor Accuracy: Plus/Minus 0.3 DEG C, Remote CJC Sensor Accuracy: Plus/Minus 0.3 DEG C, Power Dissipation: 4.6 W, Resolution: 24-Bit, Slot Width: 1, Surge Transient Immunity: Plus/Minus 2 KV Line-Earth (CM) On Shielded Signal Ports, Impedance: 1 GOHM, Rejection Ratio: Normal Mode Noise Rejection: 75 DB At 60 HZ, Common Mode Noise Rejection: 125 DB At 60 HZ 1000 OHM Differential, 120 DB At 50 HZ 1000 OHM Differential, 160 DB At 600 V 100 OHM Differential, Standard/Approvals: UL listed, CE marked, C-Tick certified, KC certified
SPECIFICATIONS
-
-
Item Name: Analog RTD And Thermocouple Module
-
Sub Brand: ControlLogix®
-
Number Of Channels: 8 (Isolated)
-
Input: Input: 1 - 500 OHM, 2 - 1000 OHM, 4 - 2000 OHM, 8 - 4000 OHM, -100 To 100 MV
-
Voltage Rating: Overvoltage Protection: Plus/Minus 30 VDC
-
Current Rating: Drawn: 200 MA At 5.1 V, 150 MA At 24 V, RTD Excitation Current: 600 MICRO-A
-
Isolation: 250 V (Continuous), Reinforced Insulation Type, Inputs To Backplane, 250 V (Continuous), Basic Insulation Type, Input To Input, Type Tested At 2300 VAC For 60 SEC, Inputs To Backplane, Type Tested At 1500 VAC For 60 SEC, Input To Input
-
Enclosure: Open Type
-
Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ On Shielded Signal Ports
-
Connection Cables: 22 - 14 AWG Solid/Stranded Shielded Copper Wire
-
Temperature Rating: 32 - 140 DEG F
-
Environmental Conditions: 5 - 95% Non-Condensing Relative Humidity, Vibration: 2 G At 10 - 500 HZ, Shock - Operating: 30 G, Non-Operating: 50 G
-
Accuracy: Calibrated Accuracy At 25 DEG C: 0.05 %, Local CJC Sensor Accuracy: Plus/Minus 0.3 DEG C, Remote CJC Sensor Accuracy: Plus/Minus 0.3 DEG C
-
Power Dissipation: 4.6 W
-
Surge Transient Immunity: Plus/Minus 2 KV Line-Earth (CM) On Shielded Signal Ports
-
Resolution: 24-Bit
-
Impedance: 1 GOHM
-
Rejection Ratio: Normal Mode Noise Rejection: 75 DB At 60 HZ, Common Mode Noise Rejection: 125 DB At 60 HZ 1000 OHM Differential, 120 DB At 50 HZ 1000 OHM Differential, 160 DB At 600 V 100 OHM Differential
-
Slot Width: 1
FEATURES
-
- Standards: UL listed, CE marked, C-Tick certified, KC certified
|
|
|
|