Image is illustrative
|
Digital Contact Output Module Point I/O, in-cabinet, 4-ch., off stage leakage 1.2A 240VAC, output NO relay, 24VDC, TS35, Allen-Bradley Code:
1734-OW4
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.054 kg/pc
|
Volume:
0.0001 m3/pc
|
|
|
|
|
Digital Contact Output Module Point I/O™, In-Cabinet , 4-ch., off stage leakage 1.2A 240VAC, output NO relay, 24VDC, TS35, Allen-Bradley
Point I/O™ Digital Contact Output Module, Type: In-Cabinet, Number Of Channels: 4, Output: Form A, N. O. Relay, Voltage Rating: 24 VDC, Current Rating: Off State Leakage: 1.2 A At 240 VAC, Isolation: 240 V Continuous, Enclosure: Open Type, Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire, Mounting: DIN Rail, Length: 0.98 IN, Width: 2.17 IN, Height: 3.03 IN, Temperature Rating: -20 To 55 DEG C, Environmental Conditions: 5 - 95% Non-Condensing Relative Humidity, Shock: 30 G Operating, 50 G Nonoperating, Vibration: 5 G At 10 - 500 HZ, Response Time: Output Delay: 26 MS (ON To OFF), Power Dissipation: 0.5 W, Operating Cycles: Contacts Life: 100000 Operations, Contact Rating: 5 - 30 VDC At 2 A Resistive, 120/240 VAC At 2 A Resistive, 1800 VA Make, 180 VA Break, Resistance: Contact: 30 MIL-OHM, Bus Rating: 80 MA, Standard/Approvals: CE-EMC marked, CE-LVD marked, C-Tick certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, ROSTECHNADZOR certified, UL-CA listed, UL-CA_HAZ listed, UL-US listed, UL-US_HAZ listed, Application: For use with ControlLogix controller
|
|
- Item Name: Digital Contact Output Module
- Type: In-Cabinet
- Sub Brand: Point I/O™
- Number Of Channels: 4
- Output: Form A, N. O. Relay
- Voltage Rating: 24 VDC
- Current Rating: Off State Leakage: 1.2 A At 240 VAC
- Isolation: 240 V Continuous
- Enclosure: Open Type
- Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire
- Mounting: DIN Rail
- Length: 0.98 IN
- Width: 2.17 IN
- Height: 3.03 IN
- Temperature Rating: -20 To 55 DEG C
- Environmental Conditions: 5 - 95% Non-Condensing Relative Humidity, Shock: 30 G Operating, 50 G Nonoperating, Vibration: 5 G At 10 - 500 HZ
- Response Time: Output Delay: 26 MS (ON To OFF)
- Power Dissipation: 0.5 W
- Operating Cycles: Contacts Life: 100000 Operations
- Bus Rating: 80 MA
- Resistance: Contact: 30 MIL-OHM
- Contact Rating: 5 - 30 VDC At 2 A Resistive, 120/240 VAC At 2 A Resistive, 1800 VA Make, 180 VA Break
Bulletin 1734 POINT I/O™ is ideal for applications requiring flexibility and low cost of ownership. Granularity of one to eight points lets you buy only the I/O you need. The compact design makes installation easier in limited panel space. The family includes POINT Guard I/O™ safety-rated I/O modules that can be used side-by-side in a standard POINT I/O system
Cost savings modular design requires less enclosure space
Up to 504 channels on a single network interface
Removable terminations accelerate commissioning
Remove and insert under power reduces maintenance time
Local autonomous control
Fast, simple configuration and integration
Full Add-on-Profiles in RSLogix 5000, no other software is needed
Channel-level diagnostics
Greater flexibility
Local control
Controlled by a single GuardLogix controller
Standards: CE-EMC marked, CE-LVD marked, C-Tick certified, GOST_R certified, KCC certified, MARINE-ABS certified, MARINE-BVS certified, MARINE-DNV certified, MARINE-GL certified, ROSTECHNADZOR certified, UL-CA listed, UL-CA_HAZ listed, UL-US listed, UL-US_HAZ listed
Applications: For use with ControlLogix controller
|
File description
|
File type
|
Download link
|
|
|
|
Product data sheet
|
PDF
|
Download link
|
|
|
|
|