Cabinet ENUX, 1200Wx2000Hx400D, frame, blank double door, rear panel, lever-operated double bar locking w. 3mm double-bit insert, modular, adj. cable entry w. sealing gasket, C3M| epoxy resin layer, IP55 IK10, NEMA12, ETA, ocean blue/ grey
Cabinet ENUX, 1200Wx2000Hx400D, frame, blank double door, rear panel, lever-operated double bar locking w. 3mm double-bit insert, modular, adj. cable entry w. sealing gasket, C3M| epoxy resin layer, IP55 IK10, NEMA12, ETA, ocean blue/ grey



Diagnostic Digital DC Input Module Point I/O, 4-ch., 10..28.8VDC, Allen-Bradley
Image is illustrative
Diagnostic Digital DC Input Module Point I/O, 4-ch., 10..28.8VDC, Allen-Bradley
Code: 1734-IB4D
Cena (indicative)
38,00 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.0408 kg/pc
Volume:
0.0001 m3/pc
Quantity:
Plus sign Minus sign
 

 

Diagnostic Digital DC Input Module Point I/O, 4-ch., 10..28.8VDC, Allen-Bradley

DESCRIPTIONS
Point I/O™ Digital DC Input Module, Type: Diagnostic, Number Of Channels: 4, Input: Field Power Bus - Supply Voltage: 24 VDC Nominal, Voltage Range: 10 - 28.8 VDC, On-State Voltage: 11 VDC (Minimum), On-State Voltage: 28.8 VDC (Maximum), On-State Current: 2 MA (Minimum), On-State Current: 15 MA (Maximum), Off-State Voltage: -3 VDC (Minimum), Off-State Voltage: 5 VDC (Maximum), Off-State Current: 1.5 MA (Minimum), Off to On Filter: 0 US, Off to On Filter: 65535 US, On to Off Filter: 0 US, Off to On Filter: 65535 US, Isolation: 50 VDC (Continuous), Reinforced Insulation Type Tested at 1000 VDC For 60 SEC, Field-Side To System, Enclosure: Open Type, Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100%AM At 1890 MHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire, Mounting: DIN Rail, Length: 2.97 IN, Width: 0.47 IN, Height: 2.2 IN, Temperature Rating: -4 To 131 DEG F, Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Shock: 30 G (Operating), 50 G (Nonoperating), Vibration: 5 G, Power Dissipation: 0.6 W At 28.8 VDC, Output Type: Current Sinking, Keyswitch Position: 1, Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports, Bus Rating: 50 MA Maximum At 5 VDC, Standard/Approvals: C/US UL listed, CE-EMC marked, C-TICK certified, GOST_R certified, KCC certified, ROSTECHNADZOR, Application: For in-cabinets
SPECIFICATIONS
  • Item Name: Digital DC Input Module

  • Type: Diagnostic

  • Sub Brand: Point I/O™

  • Number Of Channels: 4

  • Input: Field Power Bus - Supply Voltage: 24 VDC Nominal, Voltage Range: 10 - 28.8 VDC, On-State Voltage: 11 VDC (Minimum), On-State Voltage: 28.8 VDC (Maximum), On-State Current: 2 MA (Minimum), On-State Current: 15 MA (Maximum), Off-State Voltage: -3 VDC (Minimum), Off-State Voltage: 5 VDC (Maximum), Off-State Current: 1.5 MA (Minimum), Off to On Filter: 0 US, Off to On Filter: 65535 US, On to Off Filter: 0 US, Off to On Filter: 65535 US

  • Isolation: 50 VDC (Continuous), Reinforced Insulation Type Tested at 1000 VDC For 60 SEC, Field-Side To System

  • Enclosure: Open Type

  • Rfi Suppression: Radiated: 10 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100%AM At 1890 MHZ, 1 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10 VRMS With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ

  • Connection Cables: 22 - 14 AWG Solid/Stranded Copper Wire

  • Mounting: DIN Rail

  • Length: 2.97 IN

  • Width: 0.47 IN

  • Height: 2.2 IN

  • Temperature Rating: -4 To 131 DEG F

  • Environmental Conditions: Relative Humidity: 5 - 95% Non-Condensing, Shock: 30 G (Operating), 50 G (Nonoperating), Vibration: 5 G

  • Power Dissipation: 0.6 W At 28.8 VDC

  • Output Type: Current Sinking

  • Surge Transient Immunity: Plus/Minus 1 KV Line-Line (DM) And Plus/Minus 2 KV Line-Earth (CM) On Signal Ports

  • Keyswitch Position: 1

  • Bus Rating: 50 MA Maximum At 5 VDC

FEATURES
  • Input module with short-circuit and open-wire diagnostics
  • Standards: C/US UL listed, CE-EMC marked, C-TICK certified, GOST_R certified, KCC certified, ROSTECHNADZOR
  • Applications: For in-cabinets
 
 