Elit logo e-Elit - leading
electronic and automation component
online distributor
Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
Cable Lug PKK 250.10, 25mm² M10, tin-plated copper, sight hole, 100pcs/pck
Cable Lug PKK 250.10, 25mm² M10, tin-plated copper, sight hole, 100pcs/pck



Analog Output Termination Assembly ControlLogix, duplex, redundant I/O, 8-ch., 18..32VDC, 0..24mA, Allen-Bradley
Image is illustrative
Analog Output Termination Assembly ControlLogix, duplex, redundant I/O, 8-ch., 18..32VDC, 0..24mA, Allen-Bradley
Code: 1715-TADOF8
Cena (indicative)
305,80 €  /pc
Manufacturer :
Availability:
ask for dd
Weight:
0.3 kg/pc
Volume:
0.0029 m3/pc
Quantity:
Plus sign Minus sign
 

 

Analog Output Termination Assembly ControlLogix, duplex, redundant I/O, 8-ch., 18..32VDC, 0..24mA, Allen-Bradley

DESCRIPTIONS

ControlLogix® Analog Output Termination Assembly, Type: Duplex, Redundant I/O, Number Of Channels: 8, Voltage Rating: 18 - 32 VDC, Current Rating: Backplane: 0 - 24 MA Per Channel At 18 - 32 VDC, Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports, Type Tested At 500 VAC For 60 SEC, Enclosure: Open Type, Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10V rms With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ, Connection Cables: 22 - 16 AWG Solid/Stranded Copper Wire, Mounting: DIN Rail, Length: 1-5/8 IN, Width: 4-5/8 IN, Height: 6-1/2 IN, Temperature Rating: -25 To 70 DEG C, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G, Shock, Operating - DIN Rail Mount: 25 G, Panel Mount: 30 G, Shock, Non Operating - Installed: 30 G, Uninstalled: 50 G, Power Dissipation: System: 3.3 W, Field Loop: 0.64 W Per Field loop, Output Type: Analog, Surge Transient Immunity: Plus/Minus 1 KV line-line (DM) and Plus/Minus 2 KV line-earth (CM) on signal ports, Number Of Modules Supported: 2, Standard/Approvals: CE, C-tick, GOST, KC, GOST_R, KCC certified, ROSTECHNADZOR, C/US UL listed, Application: For redundant I/O

SPECIFICATIONS

  • Item Name: Analog Output Termination Assembly

  • Type: Duplex, Redundant I/O

  • Sub Brand: ControlLogix®

  • Number Of Channels: 8

  • Voltage Rating: 18 - 32 VDC

  • Current Rating: Backplane: 0 - 24 MA Per Channel At 18 - 32 VDC

  • Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports, Type Tested At 500 VAC For 60 SEC

  • Enclosure: Open Type

  • Rfi Suppression: Radiated: 20 V/M With 1 KHZ Sine-Wave 80% AM From 80 - 1000 MHZ, 10 V/M With 1 KHZ Sine-Wave 80% AM From 1000 - 2000 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 900 MHZ, 10 V/M With 200 HZ 50% Pulse 100% AM At 1890 MHZ, 3 V/M With 1 KHZ Sine-Wave 80% AM From 2000 - 2700 MHZ, Conducted: 10V rms With 1 KHZ Sine-Wave 80% AM From 150 KHZ - 80 MHZ

  • Connection Cables: 22 - 16 AWG Solid/Stranded Copper Wire

  • Mounting: DIN Rail

  • Length: 1-5/8 IN

  • Width: 4-5/8 IN

  • Height: 6-1/2 IN

  • Temperature Rating: -25 To 70 DEG C

  • Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G, Shock, Operating - DIN Rail Mount: 25 G, Panel Mount: 30 G, Shock, Non Operating - Installed: 30 G, Uninstalled: 50 G

  • Power Dissipation: System: 3.3 W, Field Loop: 0.64 W Per Field loop

  • Output Type: Analog

  • Surge Transient Immunity: Plus/Minus 1 KV line-line (DM) and Plus/Minus 2 KV line-earth (CM) on signal ports

FEATURES

  • For the field I/O channels and, by the use of coding pegs and sockets, are matched to a specific I/O module
  • Module keying can also be set in the RSLogix 5000 project
  • Field connections are made at the terminal block connectors on the termination assembly
  • 2 - On Signal Ports
  • Standards: CE, C-tick, GOST, KC, GOST_R, KCC certified, ROSTECHNADZOR, C/US UL listed
  • Applications: For redundant I/O
 
 