Elit logo e-Elit - leading
electronic and automation component
online distributor
Elit shopping basket
Items: Total:
0
0,00 €
    search
Log in
Username/Email Address:

Password:
Show all products categ.
Need assistance?
Featured Products!
I/O Chassis SLC, 13 slot, panel mount, Allen-Bradley
I/O Chassis SLC, 13 slot, panel mount, Allen-Bradley



Analog Input Termination Assembly ControlLogix, duplex, redundant I/O, 16-ch., 0..24mA 18..32VDC, TS35, Allen-Bradley
Image is illustrative
Analog Input Termination Assembly ControlLogix, duplex, redundant I/O, 16-ch., 0..24mA 18..32VDC, TS35, Allen-Bradley
Code: 1715-TADIF16
Cena (indicative)
430,70 €  /pc
Manufacturer :
Availability:
ask for dd
Weight:
0.388 kg/pc
Volume:
0.0044 m3/pc
Quantity:
Plus sign Minus sign
 

 

Analog Input Termination Assembly ControlLogix, duplex, redundant I/O, 16-ch., 0..24mA 18..32VDC, TS35, Allen-Bradley

DESCRIPTIONS

ControlLogix® Analog Input Termination Assembly, Type: Duplex, Redundant I/O, Number Of Channels: 16, Voltage Rating: 18 - 32 VDC, Current Rating: Backplane: 0 - 24 MA Per Channel At 18 - 32V DC, Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports If The 1715-TASIF16 Termination Assembly Is Fitted, Enclosure: Open Type, Connection Cables: 22 - 16 AWG Solid/Stranded Copper Wire, Mounting: DIN Rail, Length: 4-5/8 IN, Width: 1-5/8 IN, Height: 6-1/2 IN, Temperature Rating: -25 To 70 DEG C, Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G At 10 - 500 HZ, Power Dissipation: 5.28 W, Number Of Modules Supported: 2, Standard/Approvals: CE, C-tick, GOST, KC, GOST_R, KCC certified, ROSTECHNADZOR, C/US UL listed, Application: For redundant I/O

SPECIFICATIONS

  • Item Name: Analog Input Termination Assembly

  • Type: Duplex, Redundant I/O

  • Sub Brand: ControlLogix®

  • Number Of Channels: 16

  • Voltage Rating: 18 - 32 VDC

  • Current Rating: Backplane: 0 - 24 MA Per Channel At 18 - 32V DC

  • Isolation: 50 V (Continuous), Basic Insulation Type, I/O Ports To Backplane, No Isolation Between Individual I/O Ports If The 1715-TASIF16 Termination Assembly Is Fitted

  • Enclosure: Open Type

  • Connection Cables: 22 - 16 AWG Solid/Stranded Copper Wire

  • Mounting: DIN Rail

  • Length: 4-5/8 IN

  • Width: 1-5/8 IN

  • Height: 6-1/2 IN

  • Temperature Rating: -25 To 70 DEG C

  • Environmental Conditions: Relative Humidity: 5 - 95% (Non-Condensing), Vibration: 2 G At 10 - 500 HZ

  • Power Dissipation: 5.28 W

FEATURES

  • For the field I/O channels and, by the use of coding pegs and sockets, are matched to a specific I/O module
  • Module keying can also be set in the RSLogix 5000 project
  • Field connections are made at the terminal block connectors on the termination assembly
  • Fuses: 50 mA for each channel
  • Standards: CE, C-tick, GOST, KC, GOST_R, KCC certified, ROSTECHNADZOR, C/US UL listed
  • Applications: For redundant I/O
 
 