EtherNet/IP Communication Module SLC, 10/100MB/s, half or full-duplex, RJ45 cat.5, 470mA 5VDC, Allen-Bradley
EtherNet/IP Communication Module SLC, 10/100MB/s, half or full-duplex, RJ45 cat.5, 470mA 5VDC, Allen-Bradley



Connector SACC-MS-5QO-0.75 SH SCO, 1pcs/pck, Phoenix
Image is illustrative
Connector SACC-MS-5QO-0.75 SH SCO, 1pcs/pck, Phoenix
Code: 1413991
Cena
26,10 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.0417 kg/pc
Volume:
0 m3/pc
Quantity:
Plus sign Minus sign
 

 

Connector SACC-MS-5QO-0.75 SH SCO, 1pcs/pck, Phoenix

Dimensions

Wrench size, union nut 15 mm
Diameter housing 19 mm
Length 58 mm
External cable diameter 5 mm ... 9.7 mm
Stripping length of the sheath ≥ 80 mm

Ambient conditions

Ambient temperature (operation) -40 °C ... 85 °C (Plug / socket)
Ambient temperature (assembly) -5 °C ... 50 °C
Ambient temperature (operation) -40 °C ... 85 °C (Plug / socket)
Degree of protection IP65
IP67

General

Note NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.
Rated current at 40°C 4 A
Rated voltage 48 V AC
60 V DC
Number of positions 5
Insulation resistance ≥ 100 MΩ
Coding A - standard
Standards/regulations M12 connector according to IEC 61076-2-101
Shock, vibration EN 50155:2001
Signal type/category Universal
Status display No
Overvoltage category II
Degree of pollution 3
Connection method Insulation displacement connection
Conductor cross section 0.14 mm² ... 0.75 mm² (flexible)
0.14 mm² ... 0.5 mm² (solid)
Conductor cross section AWG 26 ... 18 (flexible)
26 ... 20 (solid)
Wire diameter including insulation 0.75 mm ... 2 mm
Frequency of connections between conductors of the same cross section 10
Wire insulation material PVC / PE / PP / rubber
Structure of individual litz in acc. with VDE 0295 / smallest wire diameter Class 2-6
Insertion/withdrawal cycles ≥ 100
Torque 5 Nm (Pressure nut)
Assembly instructions If the conductor is to be reconnected, it must be cut off above the last contact point.

Material

Flammability rating according to UL 94 V0
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Material of grip body Zinc die-cast, nickel-plated
Material, knurls Zinc die-cast, nickel-plated
Sealing material NBR
Standards/regulations PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, R24, and R26 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Standards and Regulations

Standards/specifications M12 connector according to IEC 61076-2-101
Shock, vibration EN 50155:2001
Flammability rating according to UL 94 V0
Standards/regulations acc. to DIN EN 45545-2
Standards/specifications M12 connector according to IEC 61076-2-101

Environmental Product Compliance

China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

ECLASS

ECLASS 10.0.1 27440102
ECLASS 11.0 27440102
ECLASS 4.0 27140800
ECLASS 4.1 27140800
ECLASS 5.0 27143400
ECLASS 5.1 27143400
ECLASS 6.0 27279200
ECLASS 7.0 27440104
ECLASS 9.0 27440102

ETIM

ETIM 6.0 EC002635
ETIM 7.0 EC002635

UNSPSC

UNSPSC 18.0 39121413
UNSPSC 19.0 39121413
UNSPSC 20.0 39121413
UNSPSC 21.0 39121413
 
 
Elit OÜ | e-post: elit@elit.ee | +372 622 9119 | 2016 ©


 