Immersion Temperature Sensor TF43-PT100, probe 200mm Ø6 ss 1.4571/ V4A, -30..150°C, 2x M12, 4wire, IP43, S+S RegeltechnikTHERMASGARD® TF43 PT100 200MM
Item No. 1101-7010-1043-000
EAN 4 251325 606095
THERMASGARD® TF 43 is a resistance thermometer with passive output, with an enclosure made of impact-resistant plastic, an enclosure cover with a snap-on lid, and a straight protective tube. THERMASGARD® TF 65 Is a resistance thermometer with a passive output, an impact-resistant plastic enclosure, an enclosure cover with quick-locking screws and a straight protective tube. Patent No. DE 10 2012 017 500.0 The built-in temperature sensor / immersion temperature sensor are electrical contact thermometers, which measure the temperatures in fluids and gases and can be installed e.g. in piping systems and containers. Use stainless steel immersion sleeves for aggressive media. The temperature sensors are used e.g. in piping systems in heating engineering, in storage systems, compact district heating stations, warm and cold water systems, oil and lubrication cycle systems in mechanical engineering, apparatus engineering, plant engineering and the entire industry sector.
Sensor |
Pt100, DIN EN 60751, class B |
Connection type |
4-wire connection |
Testing current |
approx. 1 mA |
Measuring range |
–30...+150 °C |
Ambient temperature |
–20...+100 °C |
Insulating resistance |
≥ 100 MΩ, at +20 °C (500V DC) |
Protective tube |
stainless steel, 1.4571, V4A, Ø = 6 mm,
inserted length (EL) = 50 - 400 mm
|
Electrical connection |
0.14 - 1.5 mm²
via terminal screws on circuit board
|
Enclosure |
plastic, UV-stabilised, material polyamide, 30 % glass-globe-reinforced
colour traffic white (similar to RAL 9016)
ALTF 02 with snap-on lid,
|
Enclosure dimensions |
72 x 64 x 37.8 mm (Tyr 01) |
Cable gland |
2x M 12 x 1.5 (Y-adapter); with strain relief,
exchangeable, max. inner diameter 6 mm
|
Permissible air humidity |
< 95 % r. H., non-precipitating air |
Protection class |
III (according to EN 60 730) |
Protection type |
IP 43 (according to EN 60 529) |
|