Image is illustrative
|
Inductive Sensor NJ15S+U1+N, 40x40mm flush, Sn 15mm, NC NAMUR, Sf 150Hz, PBT, -40..100°C, SIL3, 8.2V, IP68, Pepperl+Fuchs Code:
106679
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.1 kg/pc
|
Volume:
0.0002 m3/pc
|
|
|
|
|
Inductive Sensor NJ15S+U1+N, 40x40mm flush, Sn 15mm, NC NAMUR, Sf 150Hz, PBT, -40..100°C, SIL3, 8.2V, IP68, Pepperl+FuchsInductive sensor NJ15S+U1+N
- 15 mm flush
- Usable up to SIL 3 acc. to IEC 61508
Datasheet excerpt: Technical data of NJ15S+U1+N
General specifications |
Switching function | Normally closed (NC) |
Output type | NAMUR with safety function |
Rated operating distance | 15 mm |
Installation | flush |
Assured operating distance | 0 ... 12.15 mm |
Reduction factor rAl | 0.4 |
Reduction factor rCu | 0.3 |
Reduction factor r304 | 0.85 |
Output type | 2-wire |
Nominal ratings |
Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
Switching frequency | 0 ... 150 Hz |
Current consumption | |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate detected | ≤ 1 mA |
Functional safety related parameters |
MTTFd | 8110 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives |
Standard conformity | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications |
Connection type | screw terminals |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
Core cross-section | up to 2.5 mm2 |
| Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 |
| Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 |
Housing material | PBT |
Sensing face | PBT |
Degree of protection | IP68 |
General information |
Use in the hazardous area | see instruction manuals |
| Category | 1G; 2G; 1D |
|
|
|
|
|