|
|
|
Image is illustrative
|
Current/Voltage Converter KFD0-CC-Ex1, 1-ch., current/voltage input, output 4..20mA, PM/DIP switch selectable ranges, LFD, 12..35VDC LP, Pepperl+Fuchs Code:
043690
Cena (indicative)
Manufacturer
:
Availability:
21 days
|
Weight:
0.105 kg/pc
|
Volume:
0.0003 m3/pc
|
|
|
|
|
Current/Voltage Converter KFD0-CC-Ex1, 1-ch., current/voltage input, output 4..20mA, PM/DIP switch selectable ranges, LFD, 12..35VDC LP, Pepperl+FuchsCurrent/Voltage Converter KFD0-CC-Ex1
- 1-channel isolated barrier
- 24 V DC supply (loop powered)
- Current or voltage input
- Output: 4 ... 20 mA
- Potentiometer or DIP switch selectable ranges
- Line fault detection (LFD)
Datasheet excerpt: Technical data of KFD0-CC-Ex1
General specifications |
Signal type | Analog input |
Supply |
Rated voltage | 12 ... 35 V DC loop powered |
Power dissipation | 0.4 W |
Input |
Connection side | field side |
Connection | terminals 1+, 2- |
Current range | 0 ... 20 mA , load ≤ 50 Ω |
Voltage range | 0 ... 10 V , load ≥ 100 kΩ |
Output |
Connection side | control side |
Connection | terminals 9+, 8- |
Load | (U -12 V) / 0.02 A |
Current output | 4 ... 20 mA , limited to ≤ 35 mA |
Fault signal | downscaling ≤ 3 mA |
Transfer characteristics |
Rise time | 250 ms |
Indicators/settings |
Control elements | DIP-switch potentiometer |
Configuration | via DIP switches via potentiometer |
Labeling | space for labeling at the front |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity |
Galvanic isolation | EN 50178:1997 |
Degree of protection | IEC 60529:2001 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications |
Degree of protection | IP20 |
Connection | screw terminals |
Mass | approx. 100 g |
Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2 |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas |
EU-Type Examination Certificate | ZELM 00 ATEX 0034 |
| Marking | II (1)GD [EEx ia] IIC |
Certificate | TÜV 01 ATEX 1777 X |
| Marking | II 3G Ex nA II T4 |
Directive conformity | |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals |
CSA approval | |
| Control drawing | 116-0132 |
|
|
|
|
|