Featured Products!
Cable Tie GT-UV, 530/9.0 SW, 79.4kg, Polyamide 6.6, -40..85°C, UV resistant, UL94 V2, 100pcs/pck, UL E75050, Lloyd’s, GL 59425-08HH, Mil-23190D, black
Cable Tie GT-UV, 530/9.0 SW, 79.4kg, Polyamide 6.6, -40..85°C, UV resistant, UL94 V2, 100pcs/pck, UL E75050, Lloyd’s, GL 59425-08HH, Mil-23190D, black



Universal Temperature Converter KFD2-UT2-Ex1-1, 1-ch. isolated barrier, input TC/RTD/potentiometer/voltage, output 0/1..5V, PACTware, LFD, SIL2, 24VDC PR, Pepperl+Fuchs
Image is illustrative
Universal Temperature Converter KFD2-UT2-Ex1-1, 1-ch. isolated barrier, input TC/RTD/potentiometer/voltage, output 0/1..5V, PACTware, LFD, SIL2, 24VDC PR, Pepperl+Fuchs
Code: 248765
Cena (indicative)
302,70 €  /pc
Manufacturer :
Availability:
21 days
Weight:
0.1234 kg/pc
Quantity:
Plus sign Minus sign
 

 

Universal Temperature Converter KFD2-UT2-Ex1-1, 1-ch. isolated barrier, input TC/RTD/potentiometer/voltage, output 0/1..5V, PACTware, LFD, SIL2, 24VDC PR, Pepperl+Fuchs

Universal Temperature Converter KFD2-UT2-Ex1-1
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Thermocouple, RTD, potentiometer or voltage input
  • Voltage output 0/1 V ... 5 V
  • Configurable by PACTware
  • Line fault (LFD) and sensor burnout detection
  • Up to SIL 2 acc. to IEC 61508/IEC 61511

Datasheet excerpt: Technical data of KFD2-UT2-Ex1-1

Product Description
Voltage output 0/1 V ... 5 V
General specifications
Signal typeAnalog input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
Connectionterminals 14+, 15- or power feed module/Power Rail
Rated voltage20 ... 30 V DC
Ripplewithin the supply tolerance
Power dissipation/power consumption≤ 0.64 W / 0.64 W
Interface
Programming interfaceprogramming socket
Input
Connection sidefield side
Connectionterminals 1, 2, 3, 4
RTDtype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
type Cu10, Cu50, Cu100 (P50353-92)
type Ni100 (DIN 43760)
Measuring currentapprox. 200 µA with RTD
Types of measuring2-, 3-, 4-wire connection
Lead resistancemax. 50 Ω per line
Measurement loop monitoringsensor breakage, sensor short-circuit
Thermocouplestype B, E, J, K, N, R, S, T (IEC 584-1: 1995)
type L (DIN 43710: 1985)
type TXK, TXKH, TXA (P8.585-2001)
Cold junction compensationexternal and internal
Measurement loop monitoringsensor breakage
Potentiometer0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
Voltageselectable within the range -100 ... 100 mV
Input resistance≥ 1 MΩ (-100 ... 100 mV)
Output
Connection sidecontrol side
Voltage output0 ... 5 V or 1 ... 5 V ; output resistance: ≤ 5 Ω ; load: ≥ 10 kΩ
Connectionterminals 7-, 8+
Fault signaldownscale 0 V or 0.5 V, upscale 5.375 V
Transfer characteristics
Reaction timeworst case value (sensor breakage and/or sensor short circuit detection enabled)
mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s
Indicators/settings
Display elementsLEDs
Configurationvia PACTware
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 130 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-Type Examination CertificateCESI 04 ATEX 143
Marking II (1)G [Ex ia Ga] IIC
II (1)D [Ex ia Da] IIIC
I (M1) [Ex ia Ma] I
CertificateTÜV 02 ATEX 1797 X
Marking II 3G Ex nA II T4
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000
International approvals
UL approval
Control drawing116-0410
CSA approval
Control drawing116-0314 (cCSAus)
116-0347
IECEx approval
IECEx certificateIECEx TUN 07.0003
IECEx CML 16.0126X
IECEx marking[Ex ia Ga] IIC
[Ex ia Da] IIIC
[Ex ia Ma] I
Ex nA IIC T4 Gc
 
 