Featured Products!
Guard Locking Switch Guardmaster® TLS-1 GD2, 2NC safety 1NO aux., solenoid 1NO 1NC 6A 110VAC/DC, BBM, power-to-release, glass-filled PBT, ss actuator, M20, IP66/67/69K, Allen-Bradley, red
Guard Locking Switch Guardmaster® TLS-1 GD2, 2NC safety 1NO aux., solenoid 1NO 1NC 6A 110VAC/DC, BBM, power-to-release, glass-filled PBT, ss actuator, M20, IP66/67/69K, Allen-Bradley, red



Pressure, Differential Pressure Transducer PremasGard 7111-I, range/DIP: 0..100Pa⁄±100Pa, 0..300Pa⁄±300Pa, 0..500Pa⁄±500Pa, 0..1000Pa⁄±1000Pa, air media -20..50°C, output 4..20mA, inc. ASD-06, cv 24VDC, IP65, S+S Regeltechnik
Image is illustrative
Pressure, Differential Pressure Transducer PremasGard 7111-I, range/DIP: 0..100Pa⁄±100Pa, 0..300Pa⁄±300Pa, 0..500Pa⁄±500Pa, 0..1000Pa⁄±1000Pa, air media -20..50°C, output 4..20mA, inc. ASD-06, cv 24VDC, IP65, S+S Regeltechnik
Code: 1301-7112-0010-100
Cena
177,20 €  /pc
Manufacturer :
Availability:
14 days
Weight:
0.278 kg/pc
Quantity:
Plus sign Minus sign
 

 

Pressure˄differential pressure transducer Premasgard 7112 TYR2, 24VAC/DC; range/DIP: 0..100Pa⁄-100..+100Pa, 0..300Pa⁄-300..+300Pa, 0..500Pa⁄-500..+500Pa, 0..1000Pa⁄-1000..+1000Pa, 4..20mA, inc. ASD-06, IP65, S+S Regeltechnik

The calibratable, compact pressure sensors PREMASGARD® 7110 (series) are equipped with eight switchable measuring ranges and with or without optional display (eight devices in one) and are used for measuring above-atmospheric, below-atmospheric, or differential pressures in air. The piezoresistive measuring element is temperature-compensated and guarantees a high degree of reliability and accuracy. The pressure transmitters feature a pushbutton for manual zero point calibration or an automatic zero point calibration function as well as an adjustable offset.

Applications of these pressure sensors are in clean rooms; medical and filter technology; ventilation and air conditioning ducts; in spray booths; large-scale catering facilities; for monitoring filters; level measurement; or for triggering frequency converters. Media measured with these pressure transducers are air (non-precipitating), or other gaseous non-aggressive, non-combustible media. The pressure sensor has eight selectable measuring ranges and therefore, minimizes the diversity of types and inventory levels while covering a greater range of applications. The differential pressure sensor is supplied including the ASD-06 connection set (2 m connection hose, two pressure connection nipples, screws).
 
 